- 20 -
Display Function
Self-diagnosis Function
Signal Receptor
Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)
Operation Indication Lamps
On/Off
: Lights up during the system operation.
Timer or Sleep Mode
: Lights up during Timer operation or Sleep mode.
Defrost Mode
: Lights up during Defrost Mode or Hot
Start operation. (Heat pump model only)
Outdoor unit operation : Lights up during outdoor unit operation. (Cooling model only)
Auto Restart Mode
: Lights up during if Restart Button is pressed.
Auto Restart Button
: In failure of electric power, if the button is pressed the unit runs as previous
setting operation when power returns.
Forced Operation Button : Operation starts, when this button is pressed and stops when you press the
button again.
3sec
3sec
3sec
(once)
3sec
3sec
(twice)
3sec
(5times)
Error
Code
1
2
5
Error LED
(Indoor body operation LED)
Error contents
• Indoor room temperature
thermistor open/short
• Indoor pipe temperature
thermistor open/short.
• Outdoor pipe temperature
thermistor open/short.
• Poor communication.
• Indoor TH assy check
• Outdoor TH assy check
• Communication line/circuit
check
SVC check point
Содержание LS300CE
Страница 55: ... 55 Electronic Control Device 1 INDOOR UNIT P W B ASSEMBLY P No 6871A10153 PCB ASSEMBLY MAIN ...
Страница 56: ... 56 TOP VIEW BOTTOM VIEW 2 OUTDOOR UNIT P W B ASSEMBLY ...
Страница 57: ... 57 3 DISPLAY P W B ASM ...
Страница 58: ... 58 Schematic Diagram 1 Indoor Unit ...
Страница 64: ...P No 3828A20390R May 2004 Printed in Korea ...