18
Air Conditioner
Operating Instructions
Forced operation
Forced operation is used when the remote controller can't be used. The operation will be started if the ON/OFF
button is pressed. If you want to stop the operation, re-press the button.
ON/OFF Button
Heat pump Model
Cooling Model
Room Temp. ≥ 24°C(75.2°F)
21°C(69.8°F) ≤ Room Temp. < 24°C(75.2°F)
Room Temp. < 21°C(69.8°F)
Operating mode
Cooling
Cooling
Healthy Dehumidification
Heating
Indoor FAN Speed
High
High
High
High
Setting Temperature
22°C(71.6°F)
22°C(71.6°F)
23°C(73.4°F)
24°C(75.2°F)
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature
and resets in 18 minutes. During test operation, if remote controller signal is received, the unit operates as remote controller
sets. If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1
'beep'. If you want to stop the operation, re-press the button.
This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6
seconds. The unit will beep twice and the lamp will blink 6 times.
To enable it, press the button again for 6 seconds. The unit will beep twice and the blue lamp will blink 4 times.
NOTE
If you do not have the remote controller around here, you can start to operate the forced operation.
If you force to close the front panel, some parts may be damaged.
NOTE
This function is useful in the situation of power failure.
When power regains after a failure this feature restore the previous operating condition
and the air conditioner will run in the same settings.
Auto Restart Function
ON/OFF Button