6. Poor/Over cooling in Fresh food section
1. Poor cooling in Fresh
food section
Symptom
Check Point
1. Check the sensor resistance
2. Check the air flow
3. Check the air temperature
4. Check the R-Damper
5. Check the Fan motor sticky
6. Check the Fan motor voltage
CON
4
R1SNR
15
th
pin ~
16
th
pin
Resistance
[Ω]
23ºF /-5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
Duct
Status
Air Flow
Windy
Air Temperature
Cold
Fan Motor
TEST MODE 1
Voltage
[V]
CON
3
13
th
pin ~ 1
6
th
pin
10
.8
~1
3.2
VDC
CON
3
13
th
pin ~ 1
5
th
pin
2~4.5 VDC
CON
3
13
th
pin ~ 1
4
th
pin
Not 0V, 5V