Temperature compensation table at the refrigerator is as follows:
u
Temperature compensation at the freezer is also performed in the same manner as refrigerator. Temperature
compensation value is equivalent to two times the refrigerator.
u
This circuit is a circuit to enter the necessary level of temperature compensation for adjusting different temperature every
model at the refrigerator into MICOM.
EXPLANATION FOR MICOM CIRCUIT
- 43 -
470
Ω
2 k
Ω
3.3 k
Ω
5.6 k
Ω
8.2 k
Ω
10 k
Ω
12 k
Ω
18 k
Ω
33 k
Ω
56 k
Ω
180 k
Ω
No
0.5 °C
1 °C
1.5 °C
2 °C
2.5 °C
3 °C
3.5 °C
4 °C
4.5 °C
5 °C
470
Ω
[0.9 °F] [1.8 °F] [2.7 °F] [3.6 °F] [4.5 °F] [5.4 °F] [6.3 °F] [7.2 °F] [8.1 °F]
[9 °F]
change
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
0.5 °C
No
0.5 °C
1 °C
1.5 °C
2 °C
2.5 °C
3 °C
3.5 °C
4 °C
4.5 °C
2 k
Ω
[0.9 °F]
[0.9 °F] [1.8 °F] [2.7 °F] [3.6 °F] [4.5 °F] [5.4 °F] [6.3 °F] [7.2 °F]
[8.1 °F]
Down
change
Up
Up
Up
Up
Up
Up
Up
Up
Up
1 °C
0.5 °C
No
0.5 °C
1 °C
1.5 °C
2 °C
2.5 °C
3 °C
3.5 °C
4 °C
3.3 k
Ω
[1.8 °F] [0.9 °F]
[0.9 °F] [1.8 °F] [2.7 °F] [3.6 °F] [4.5 °F] [5.4 °F] [6.3 °F]
[7.2 °F]
Down
Down
change
Up
Up
Up
Up
Up
Up
Up
Up
1.5 °C
1 °C
0.5 °C
No
0.5 °C
1 °C
1.5 °C
2 °C
2.5 °C
3 °C
3.5 °C
5.6 k
Ω
[2.7 °F] [1.8 °F] [0.9 °F]
[0.9 °F] [1.8 °F] [2.7 °F] [3.6 °F] [4.5 °F] [5.4 °F]
[6.3 °F]
Down
Down
Down
change
Up
Up
Up
Up
Up
Up
Up
2 °C
1.5 °C
1 °C
0.5 °
No
0.5 °C
1 °C
1.5 °C
2 °C
2.5 °C
3 °C
8.2 k
Ω
[3.6 °F] [2.7 °F] [1.8 °F] [0.9 °F]
[0.9 °F] [1.8 °F] [2.7 °F] [3.6 °F] [4.5 °F]
[5.4 °F]
Refrigerator
Down
Down
Drop
Down
change
Up
Up
Up
Up
Up
Up
(RCR1)
2.5 °C
2 °C
1.5 °C
1 °C
0.5 °C
No
0.5 °C
1 °C
1.5 °C
2 °C
2.5 °C
10 k
Ω
[4.5 °F] [3.6 °F] [2.7 °F] [1.8 °F] [0.9 °F]
[0.9 °F] [1.8 °F] [2.7 °F] [3.6 °F]
[4.5 °F]
Down
Down
Down
Down
Down
change
Up
Up
Up
Up
Up
3 °C
2.5 °C
2 °C
1.5 °C
1 °C
0.5 °C
No
0.5 °C
1 °C
1.5 °C
2 °C
12 k
Ω
[5.4 °F] [4.5 °F] [3.6 °F] [2.7 °F] [1.8 °F] [0.9 °F]
[0.9 °F] [1.8 °F] [2.7 °F]
[3.6 °F]
Down
Down
Down
Down
Down
Down
change
Up
Up
Up
Up
3.5 °C
3 °C
2.5 °C
2 °C
1.5 °C
1 °C
0.5 °C
No
0.5 °C
1 °C
1.5 °C
18 k
Ω
[6.3 °F] [5.4 °F] [4.5 °F] [3.6 °F] [2.7 °F] [1.8 °F] [0.9 °F]
[0.9 °F] [1.8 °F]
[2.7 °F]
Down
Down
Down
Down
Down
Down
Down
change
Up
Up
Up
4 °C
3.5 °C
3 °C
2.5 °C
2 °C
1.5 °C
1 °C
0.5 °C
No
0.5 °C
1 °C
33 k
Ω
[7.2 °F] [6.3 °F] [5.4 °F] [4.5 °F] [3.6 °F] [2.7 °F] [1.8 °F] [0.9 °F]
[0.9 °F]
[1.8 °F]
Down
Down
Down
Down
Down
Down
Down
Down
change
Up
Up
4.5 °C
4 °C
3.5 °C
3 °C
2.5 °C
2 °C
1.5 °C
1 °C
0.5 °C
No
0.5 °C
56 k
Ω
[8.1 °F] [7.2 °F] [6.3 °F] [5.4 °F] [4.5 °F] [3.6 °F] [2.7 °F] [1.8 °F] [0.9 °F]
[0.9 °F]
Down
Down
Down
Down
Down
Down
Down
Down
Down
change
Up
5 °C
4.5 °C
4 °C
3.5 °C
3 °C
2.5 °C
2 °C
1.5 °C
1 °C
0.5 °C
No
180 k
Ω
[9 °F]
[8.1 °F] [7.2 °F] [6.3 °F] [5.4 °F] [4.5 °F] [3.6 °F] [2.7 °F] [1.8 °F] [0.9 °F]
Down
Down
Down
Down
Down
Down
Down
Down
Down
Down
change
Modification
resistance
Current
resistance
Содержание LRSPC2051AB
Страница 41: ...2 GR C247 B247 C207 B207 EXPLANATION FOR MICOM CIRCUIT 41 b e c f a d Speed Speed ...
Страница 48: ...2 GR C247 B247 C207 B207 EXPLANATION FOR MICOM CIRCUIT 48 ...
Страница 49: ...3 2 Parts list 1 GR P247 L247 P207 L207 EXPLANATION FOR MICOM CIRCUIT 49 ...
Страница 50: ...EXPLANATION FOR MICOM CIRCUIT 50 WATER SUPPLY S W ...
Страница 51: ...2 GR C247 B247 C207 B207 EXPLANATION FOR MICOM CIRCUIT 51 ...
Страница 52: ...EXPLANATION FOR MICOM CIRCUIT 52 WATER SUPPLY S W ...
Страница 53: ...3 3 DISPLAY ASSEMBLY part diagram 1 GR P247 L247 P207 L207 EXPLANATION FOR MICOM CIRCUIT 53 ...
Страница 54: ...2 GR C247 B247 C207 B207 EXPLANATION FOR MICOM CIRCUIT 54 DOUBLE SIDE TAPE SPREAD SHEET ...
Страница 58: ...EXPLANATION FOR MICOM CIRCUIT 58 PCB ASSEMBLY DISPLAY ...
Страница 59: ...2 GR C247 B247 C207 B207 EXPLANATION FOR MICOM CIRCUIT 59 PWBASSEMBLY MAIN ...
Страница 60: ...EXPLANATION FOR MICOM CIRCUIT 60 PCB ASSEMBLY DISPLAY ...
Страница 67: ...CIRCUIT 67 ...
Страница 68: ...CIRCUIT 68 ...
Страница 122: ...P No 3828JD8471K SEP 2002 Printed in Korea ...