-29-
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Setting time
does not count
down when
touching START
pad.
2. Fan motor or
oven lamp do
not turn on.
No continuity.
Continuity.
Continuity
Defective Power
PCB assembly.
Loose connection.
Replace Power
PCB assembly.
Connect them
tightly.
No continuity
Abnormal
Check fan motor.
Defective fan motor.
Replace fan motor.
Abnormal
Normal
Check oven lamp.
Defective oven lamp.
Replace oven lamp.
Defective
secondary switch.
Replace
secondary switch.
Check continuity
of secondary
switch (with
door closed).
Check the con-
nection between
CN1 connector
and PCB
assembly.
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while desired
program times are set and START pad is touched.
(TROUBLE 4) Oven seems to be operating but little heat is produced in oven load.
NOTE : Simple test of power output-conducted by heating one liter water for one min. if available.
Minimum 8.5°C temperature rise is normal condition.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is low
Lower than 90% of
rating voltage.
Normal
Defective
Magnetron.
Replace
Magnetron.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
Содержание LRMM1430SB
Страница 8: ...6 OVERALL CIRCUIT DIAGRAM A SCHEMATIC DIAGRAM 7 Figure 3 ...
Страница 9: ...B MATRIX CIRCUIT FOR TOUCH KEY BOARD 8 Figure 4 ...
Страница 32: ... 31 INTRODUCTION EXPLODED VIEW ...
Страница 33: ... 32 DOOR PARTS 14970A 14026A WTP002 13806A 13213A 13552A 13536A 13581A 268711 WTP002 23506A 13551A 15006A ...
Страница 34: ... 33 CONTROLLER PARTS 268711 WTP002 23506A 13551A ...
Страница 36: ... 35 LATCH BOARD PARTS WSZ085 43500A 466001 43501A 466003 466001 ...
Страница 37: ... 36 OVEN INTERIOR PARTS WTT028 WTT021 54974T 56501A 56930V 56912B 43500A 56324A WSZ002 ...
Страница 43: ... 42 SCHEMATIC DIAGRAM OF P C B ...
Страница 44: ... 43 PRINTED CIRCUIT BOARD KEY PCB MAIN PCB ...
Страница 48: ...P NO 3828W5S3066 May 2003 Printed in Korea ...