5-10
COMPONENTS
TEST PROCEDURE
RESULTS
RELAY 2
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
Measure the resistance.
(Ohm-meter scale: R x 1)
Normal:
A:Approx. 85 ~ 100 ohm.
B:Approx. 10 ~ 25 ohm.
Abnormal: Infinite or several
ohm.
Normal: Approx. 100 ~ 150 ohm
Abnormal: Infinite or several
ohm.
POWER
LEVEL
1
2
3
4
5
6
7
8
9
10
4 sec
6 sec
8 sec
10 sec
12 sec
14 sec
16 sec
18 sec
20 sec
22 sec
18 sec
16 sec
14 sec
12 sec
10 sec
8 sec
6 sec
4 sec
2 sec
0 sec
Measure the resistance.
(Ohm-meter scale: R x 1)
Содержание LRM1250W
Страница 10: ...SCHEMATIC DIAGRAM 4 4 ...
Страница 27: ...DOOR CONTROL PANEL BASE PLATE OUTER CASE LATCH BOARD INTERIOR 6 1 EXPLODED VIEW INTRODUCTION EV ...
Страница 28: ...6 2 DOOR PARTS 13552A 13213A 13581A 14970A 14026A 13536A 15006A 14890A 13720D 143501 EV ...
Страница 29: ...6 3 CONTROLLER PARTS 24781M 23506A 23572A 24510L 24970A 250201 268711 WTP018 EV ...
Страница 30: ...6 4 OVEN CAVITY PARTS 33390G WTT010 WSZ185 33112U 35889A 36549S WTP013 33052A 948502 EV ...
Страница 31: ...6 5 LATCH BOARD PARTS WSZ085 466001 466003 466001 43500A EV ...
Страница 33: ...6 7 BASE PLATE PARTS 56170D WSZ002 WTT021 63302A 65006B 63303A EV ...
Страница 34: ......