7-19
TROUBLESHOOTING
Replace the Relay
PCB
Is the DLB relay normal?
Measure the resistance
Normal: infinite
Abnormal : shorted
Yes
No
3
DLB
Relay
Tab 23(or Tab 24)
and Tab 25 : RY13
Replace the Main
PCB
Is the value of thermistor
normal? (Refer below)
Check with the test mode
To enter the test mode, follow
these steps:
(1) press the CLEAR button
(2) press the BAKE and BROIL buttons at the same
time
(3) press the upper BAKE and SPEED BROIL
buttons at the same time again.
(4) press the NUM 3 button
Normal: Thermistor value at room temp is from 70℉
to 90℉
No
4
Current Oven
Temp