4-1
COMPONENT TEST
NOTE:
1. The most common cause for control failure is corrosion on connectors.
Therefore, disconnecting and reconnecting wires will be necessary throughout test procedures
2. ALL units in the first few days of use should be checked for mis-wiring or loose connections
1. All/tests/checks should be made with a VOM or DVM having a sensitivity of 20,000 ohms per-volt DC, or
greater.
2. Check all connections before replacing components, looking for broken or loose wires, Failed terminals, or
wires not pressed into connectors far enough.
3. Resistance checks must be made with power cord unplugged from outlet, and with wiring harness or
connectors disconnected.
NOTE: Below
Ω
value were tested at room temperature (77F/25°C)
Before testing any of components, perform the following checks:
WARNING
• Disconnect power supply cord from the outlet before servicing
• Replace all panels and parts before operating
• Reconnect all grounding devices after servicing
- Failure to do so can result in death or electrical shock
!
Convection Motor
1. Refer to page 3-12 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1)
Components
Test procedures
Results
Normal: Approximately
37
Ω
If not replace
Abnormal: Infinite (open)
below 5
Ω
(shorted)
Содержание LRE3085ST
Страница 45: ...5 3 COMPOSITION OF CONTROL Key Matrix Key Matrix ...
Страница 48: ...5 6 COMPOSITION OF CONTROL Cook top display PCB Cook top display PCB Key Pad Key Pad ...
Страница 87: ...12 4 BROIL WARMNING DRAWER CONV BAKE CONV ROAST SELF CLEANING ...
Страница 88: ...RR Cook top Element LR Cook top Element CR Warming Zone 12 5 ...
Страница 89: ...12 6 LF Cook top Element RF Cook top Element ...
Страница 93: ... 13 5 COOKTOP PARTS 3057 3014 3056 3302 3302 3303 3303 3401 3022 3204 3207 3401 3204 3204 3204 EV ...
Страница 96: ......