background image

9

ENGLISH

ELECTRICAL CONNECTIONS

4-WIRE CONNECTION WITH 

A POWER SUPPLY CORD

•  

 Only a 4-conductor power-supply cord kit rated 
120/240 volts, 50 amperes and marked for use 
with ranges with closed-loop connectors or 
open-end spade lugs with upturned ends shall 
be used. The middle (neutral) wire of the power 
cord or 4-wire conduit has to be connected to 
the middle post of the main terminal block. 
The  other  two  wires  of  the  power  cord  or 
conduit have to be connected to the outside 
posts of the main terminal connection block. 
The 4th ground wire must be connected to the 
frame of the range with the ground screw.

-   Failure to do so can result in electrical shock, 

severe personal injury or death.

 WARNING

Install the power cord as follows:

For power cord installations, Hook the strain relief over 
the power cord hole (1

3

/

8

”) located below the rear of 

lower oven. Insert the power cord through the strain 
relief and tighten it. (Refer to Figure 7.)

DO N

OT install the power cord without a strain relief.

1.  Remove the lower 3 screws from the terminal block 

and retain them. (Refer to Figure 9.)

2.  Remove  ground  strap  and  discard  as  show  in  in  

Figure 9.

3.  Insert the ground screw into the power cord ground 

wire terminal ring and secure it to the range frame.

4.  Insert the 3 screws through each power cord terminal ring 

and into the lower terminals of the terminal block. Make 
sure that the center wire (white/neutral) is connected to 
the center lower position of the terminal block.

5.  Tighten 3 screws securely into the terminal block.

4-wire connection

Terminal 

block

Conduit

connection plate

Ground screw

Remove ground

strap and discard

Ground 

strap

Black White Red

FIgURE 9

3-WIRE CONNECTION: CONDUIT

Install the conduit as follows:

Remove the Conduit connection plate from the rear of 
lower  oven  and  rotate  it  as  shown  in  Figure  5. The 
conduit hole (1

1

/

8

") must be used.

First, prepare the conduit wires as shown in Figure 10.
 

3 wire 

4 wire

Conduit

connection 

plate

     or     

Ground 

strap

FIgURE 10

Second, install conduit as shown in Figure 6.
For conduit installations, after purchasing a strain relief, 
insert  it  in  the  conduit  hole  (1

1

/

8

”). Then  install  the 

conduit through the body of strain relief and fasten the 
strain relief with its ring. Reinstall the bracket.
For conduit connections :
If the wire in the conduit is copper it must be 8 or 10 
AWG wiring.
If the wire in the conduit is aluminum it must be 6 or 8 
AWG wiring.
1.  Loosen the lower 3 screws from the terminal block. 

Refer to Figure 11.)

2.  Insert the bare wire (white/neutral) end through the 

center terminal block opening. Do not remove ground 
strap connections.

3.  Insert the two side bare wire ends into the lower left 

and the lower right terminal block opening. Tighten 
the  3  screws  securely  into  the  terminal  block. 
(approximately 35 - 50 IN-LB)

4. Refer to page 11.

3-wire connection

Terminal 

block

Wire ends

Conduit

connection plate

Black White

Red

FIgURE 11

3 wire

Содержание LRE3023SB

Страница 1: ...SB LRE3025SW LRE3023ST LRE3023SB LRE3023SW www lg com INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range ENGLISH Printed on 100 Recycled Paper ESPAÑOL ...

Страница 2: ...NSTALL RANGE 6 Installation Drawings 7 ELECTRICAL CONNECTIONS 7 Electrical Connection Requirements 7 Connect Range Cord 8 3 Wire Connection With a Power Supply Cord 9 4 Wire Connection With a Power Supply Cord 9 3 Wire Connection Conduit 1 0 4 Wire Connection Conduit 11 INSTALL THE RANGE 1 1 Anti Tip Device Installation 1 1 Final Installation ...

Страница 3: ... could be tipped and injury might result from spilled hot liquid food or the range itself If the range is pulled away from the wall for cleaning service or any other reason ensure that the Anti Tip de vice is properly reengaged when the range is pushed back against the wall Install the Anti Tip Brackets A child or adult can be killed when the range is tipped Anti Tips will fasten the range by hold...

Страница 4: ...nnectors or open end spade lugs with upturned ends shall be used The middle neutral wire of the power cord or 4 wire conduit has to be connected to the middle post of the main terminal block The other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block The 4th ground wire must be connected to the frame of the range with the ground ...

Страница 5: ...s from the oven compartments before connecting the electrical supply to the range Observe all governing codes and ordinances Be sure to leave these instructions with the consumer NOTE Keep these instructions with your owner s manual for future reference As when using any appliance generating heat there are certain safety precautions you should follow Be sure your range is installed and grounded pr...

Страница 6: ... Cabinet storage space located above the surface units should be avoided Install a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets if cabinet storage is to be provided heated surface elements can be reduced CAUTION MINIMUM DIMENSIONS Figure 2 30 76 2 cm minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or me...

Страница 7: ... the power is prohibited The way to connect the power cord and plug directly is strongly recommended Electrical ground is required on this appliance You should make sure that the power cord is not pinched by the range or heavy objects Failure to do so can result in serious burns or electrical shock WARNING Range rating watts rating of power supply cord kit amperes Diameter inches of Range connecti...

Страница 8: ... cord through the strain relief and tighten it Refer to Figure 7 DO NOT install the power cord without a strain relief 1 Remove the lower 3 screws from the terminal block and retain them Refer to Figure 8 2 Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block Make sure that the center wire white neutral is connected to the center lower positi...

Страница 9: ...l block Make sure that the center wire white neutral is connected to the center lower position of the terminal block 5 Tighten 3 screws securely into the terminal block 4 wire connection Terminal block Conduit connection plate Ground screw Remove ground strap and discard Ground strap Black White Red FIgURE 9 3 WIRE CONNECTION CONDUIT Install the conduit as follows Remove the Conduit connection pla...

Страница 10: ...Figure 12 Do not discard any screws 4 Attach the ground bare wire end to range frame and secure it in place with the ground screw Refer to figure 12 5 Insert the bare wire white neutral end through the center terminal block opening 6 Insert the two side bare wire ends into the left and the right terminal block opening Tighten the 3 screws securely into the terminal block approximately 35 50 IN LB ...

Страница 11: ...omplete the installation Read and follow range installation instruction sheet template 2 Level the range Level the range by adjusting the leveling legs with a wrench Leg leveler Raise range Lower range Use a level to check your adjustments Place the level diagonally on the oven rack and check each direction for level First check direction Å After check direction Ç If the level doesn t show level o...

Страница 12: ...12 MEMO ...

Страница 13: ... Korea www lg com Register your product Online LG Customer Information Center 1 800 243 0000 1 888 542 2623 USA Consumer User CANADA For inquires or comments visit www lg com or call Printed on 100 Recycled Paper ...

Отзывы: