7-3 RESISTANCE SPECIFICATION OF SENSOR
• The resistance of the SENSOR has a ±5% common difference.
• Measure the resistance of the SENSOR after leaving it for over 3 minutes in the measuring temperature.
This delay is necessary due to sensor response speed.
• Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB ASSY, MAIN.
TEMPERATURE DETECTED
RESISTANCE OF FREEZER
RESISTANCE OF REFRIGERATOR &
BY SENSOR
SENSOR
DEFROST SENSOR & ROOM SENSOR
- 20 ˚C
22.3 K
Ω
77 K
Ω
- 15 ˚C
16.9 K
Ω
60 K
Ω
- 10 ˚C
13.0 K
Ω
47.3 K
Ω
- 5 ˚C
10.1 K
Ω
38.4 K
Ω
0 ˚C
7.8 K
Ω
30 K
Ω
+ 5 ˚C
6.2 K
Ω
24.1 K
Ω
+ 10 ˚C
4.9 K
Ω
19.5 K
Ω
+ 15 ˚C
3.9 K
Ω
15.9 K
Ω
+ 20 ˚C
3.1 K
Ω
13 K
Ω
+ 25 ˚C
2.5 K
Ω
11 K
Ω
+ 30 ˚C
2.0 K
Ω
8.9 K
Ω
+ 40 ˚C
1.4 K
Ω
6.2 K
Ω
+ 50 ˚C
0.8 K
Ω
4.3 K
Ω