CAUTION

Operation

Always check for gas
(refrigerant) leakage after
installation or repair of product.

• Low refrigerant levels may cause

failure of product.

Install the drain hose to
ensure that water is drained
away properly.

• A bad connection may cause

water leakage.

Keep level even when
installing the product. 

• To avoid vibration or water

leakage.

Do not install the product where the
noise or hot air from the outdoor unit
could damage the neighborhoods.

• It may cause a problem for your

neighbors.

Use two or more people to
lift and transport the
product. 

• Avoid personal injury.

Do not install the product where
it will be exposed to sea wind
(salt spray) directly.

• It may cause corrosion on the

product. Corrosion, particularly on
the condenser and evaporator fins,
could cause product malfunction or
inefficient operation.

90

°

When the product is not be used for a long
time, disconnect the power supply plug or
turn off the breaker.

• There is risk of product damage or failure, or

unintended operation.

Take care to ensure that nobody could step
on or fall onto the outdoor unit.

• This could result in personal injury and product

damage.

Do not expose the skin directly to cool air for
long periods of time. 
(Don't sit in the draft.)

• This could harm to your health.

Do not use the product for special purposes, such as
preserving foods, works of art, etc. It is a consumer air
conditioner, not a precision refrigeration system.

• There is risk of 

damage or 
loss of property.

Содержание LPNC2863EC0

Страница 1: ...oroughly before installing and operating Your Air Conditioner Please retain this owner s manual for future reference after reading it thoroughly Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 61000 2 61000 3 Norm website http www lgservice com ...

Страница 2: ... in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be s...

Страница 3: ...e sure to follow the instruction WARNING Installation Do not use a defective or underrated circuit breaker Use this appliance on a dedicated circuit There is risk of fire or electric shock For electrical work contact the dealer seller a qualified electrician or an Authorized Service Center Do not disassemble or repair the product There is risk of fire or electric shock Always ground the product Th...

Страница 4: ...to the product Be sure the installation area does not deteriorate with age If the base collapses the air conditioner could fall with it causing property damage product failure and personal injury Do not plug or unplug the power supply plug during operation There is risk of fire or electric shock Do not touch operate the product with wet hands There is risk of fire or electrical shock Do not place ...

Страница 5: ...risk of electric shock or fire Stop operation and close the window in storm or hurricane If possible remove the product from the window before the hurricane arrives There is risk of property damage failure of product or electric shock Do not open the inlet grill of the product during operation Do not touch the electrostatic filter if the unit is so equipped There is risk of physical injury electri...

Страница 6: ...he product where it will be exposed to sea wind salt spray directly It may cause corrosion on the product Corrosion particularly on the condenser and evaporator fins could cause product malfunction or inefficient operation 90 When the product is not be used for a long time disconnect the power supply plug or turn off the breaker There is risk of product damage or failure or unintended operation Ta...

Страница 7: ...t malfunction or damage Do not insert hands or other objects through the air inlet or outlet while the product is operated There are sharp and moving parts that could cause personal injury Do not drink the water drained from the product It is not sanitary and could cause serious health issues Use a firm stool or ladder when cleaning or maintaining the product Be careful and avoid personal injury R...

Страница 8: ...pecial purpose e g preserving precision devices food pets plants or art objects Such use may damage your properties 1 Do not touch the metal parts of the unit when removing the filter Injury can occur 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to electric shock 3 When cleaning the unit first make sure that the power and breaker are t...

Страница 9: ...Terminal 6 Refrigerant Pipe Port 1 3D Wide Airflow System 3D Wide Airflow makes clear a dead Zone to cool the indoor evenly within a Early time 2 Super Energy Efficiency MPS Multi Power System Cycle Saves the energy by 1 2 Comp Operation 3 Neo Plasma Air Purifying System Neo Plasma Air Purifying system includes 14 level bio enzyme filter System featuring heath filter system and Clean Filter System...

Страница 10: ... Display LP C Model 6 Plasma Air Cleaner Operation Display 7 Soft Dry Operation Display 8 Heating Operation Display LP Z H Model 9 Electric Heater Operation Display LP Z Model Only 10 Defrost Operation Display LP Z H Model 11 Outdoor Unit Operation Display 12 Off Timer Operation Display 13 Self Cleaning Display light becomes faint after 10 seconds in controlling display The function of this Manual...

Страница 11: ...If you select 0 Timer function will be canceled 7 Time Set Button It shows current time and can be set 8 Self Cleaning Operation Button 9 Electric Heater On Off Button LP Z Model Only 10 Display Window 11 Mode Selection Button 12 Indoor Fan Speed Selection Button 13 Temperature Setting Button 14 Auto Airflow direction Control Button The Top Vane swings up and down 15 Auto Airflow direction Control...

Страница 12: ...e the cover according to the arrow direction 2 Insert two batteries Be sure that the and directions are correct Be sure that both batteries are new 3 Re attach the cover Slide the cover into back position Do not use rechargeable batteries such batteries as different from standard dry cells in shape dimensions and performance Change the batteries with a new one if the remote control does not work p...

Страница 13: ... ON OFF MODE FAN SPEED ON OFF MODE Cooling Operation Mode Press the on off button Press the Mode Button Select the cooling operation Mode Set the temperature lower than the room temperature The temperature can be set within a range of 16 C 30 C by 1 C When you finish the temperature setting Set the Fan Speed Each time the Fan Speed Button is pressed or fan speed key is touched the Fan Speed mode i...

Страница 14: ...oo warm or hot FAN SPEED ON OFF MODE Low High Mid Auto Changeover Operation LP Z H Model Press the on off button Press the Mode Button Select the Auto Changeover Operation Mode For cooling or heating operation set the desired indoor temperature by room temperature setting buttons Set the fan speed by remote controller or display panel on front door Button is pressed the Fan Speed mode is shifted ...

Страница 15: ...al Intelligence Operation The indoor fan speed is automatically set to low and can be set fan speed Auto Operation LP C Model Press the on off button or touch the anyplace of touch panel and touch the on off key Press the Mode Button Select the Artificial Intelligence Operation Mode Set the temperature lower than the room temperature The temperature can be set within a range of by 1 level This ind...

Страница 16: ... ON OFF MODE FAN SPEED ON OFF MODE FAN SPEED ON OFF MODE Soft Dry Operation Press the on off button Press the Mode Button Select the Soft Dry Operation Mode Set the temperature lower than the room temperature The temperature can be set within a range of 16 C 30 C by 1 C During Softy Dry Operation The indoor fan speed is automatically set to low and can be set fan speed ...

Страница 17: ... ON OFF MODE FAN SPEED ON OFF MODE FAN SPEED ON OFF MODE Heating Operation Mode LP Z H Mode Press the on off button Press the Mode Button Select the Heating Operation Mode Set the temperature lower than the room temperature The temperature can be set within a range of 16 C 30 C by 1 C Set the Fan Speed Each time the Button is pressed the Fan Speed mode is shifted ...

Страница 18: ...N OFF MODE Energy Saving Mode Cooling Soft Dry Operation Only Press the on off button Select Energy Saving Operation Press the Energy Operation Button on the remote controller To cancel the Energy Saving mode Press the Energy Saving Button Again and the unit will operate on Cooling Auto Soft Dry mode ...

Страница 19: ...r Purifying Operation On Off Button Operation will start when the button is pressed and stop when the button is pressed again Select Fan speed The display shows low fan speed at the initial condition You can operate the Plasma Air Purifying under the unit operation of cooling heating soft dry or Auto mode 1 Press the on off Button 2 Select the desired Operation mode 3 Press the Plasma Air Purifyin...

Страница 20: ...zy mode however the Turbo Z Cooling function is not available In order to return to the normal cooling mode from the Turbo Z Cooling mode you just press either the operation mode selection button or the Turbo Z Cooling button again NOTICE Press the on off button Press the Turbo Z Cooling button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode To c...

Страница 21: ...ow High Mid FAN SPEED ON OFF MODE Electric Heater Operation Mode LP Z Model Press the on off button Select Heating Operation Mode Press E Heater Operation Button on the remote controller Set the temperature lower than the room temperature The temperature can be set within a range of 16 C 30 C by 1 C Set the Fan Speed Each time the Button is pressed the Fan Speed mode is shifted ...

Страница 22: ... off Display shows SC and self cleaning operates for 1 minutes If selecting the self cleaning button when unit is off Display shows for 4 seconds When unit is on it memorizes Reserved self cleaning operation 22 Floor Standing Air Conditioner Operating Instructions Self Cleaning Operation Air Purifying Operation only 1 CAUTION When plasma air cleaner operates only self cleaning shows display but do...

Страница 23: ...ch any key on Display panel it will immediately display which means Display panel is Locked All the key on the indoor unit Display panel will not work But the key on the remote controller will work For releasing child lock Operation Press the fan speed and high temperature setting keys simultaneously for 3 seconds again The unit will respond with beep Child Lock Operation will removed Auto restart...

Страница 24: ...er Setting Procedure OFF TIMER Setting or CANCEL When you finish the Off Timer setting the Timer indicator lights off Press the on off button Press the Timer Button During off timer operation if you press the Timer Button the rest time will be displayed If you press the button the selected off timer is displayed as follows If you select the Off Timer function will be cancelled ...

Страница 25: ...in water After water cleaning dry it throughout in a shade to prevent trouble 3 HEPA filter should be replaced with new every 1 year HEPA filter should not be cleaned with water CAUTION The period of filter cleaning Exchange can be different depends on circumstance Maintenance and Service Owner s Manual 25 ENGLISH Maintenance and Service Indoor Unit WARNING Turn the system off before cleaning To c...

Страница 26: ...changer coils and panel vents of the outdoor unit should be checked regularly If clogged with dirt or soot the heat exchanger and panel vents may be professionally steam cleaned Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs NOTICE Air Intake Vent Rear Air Outlet Vent When the inner side color of air cleaner changes into yellowish dry it ...

Страница 27: ...bstructed and that there is a clearance of over 20 between the back of the air conditioner and the wall or fence behind it 4 Close all doors and windows and check for any source of heat in the room Before calling for service please review the following list of common problems and solutions The air conditioner is operating normally when You hear a pinging noise This is caused by water being picked ...

Страница 28: ...into the outlet Check the house fuse circuit breaker box and replace the fuse or reset the breaker If power failure occurs turn the mode control to Off When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Turn the knob to a higher number The h...

Страница 29: ...P No MFL37921104 Printed in Korea After reading this manual keep it in a place easily accessible to the user for future reference ...

Отзывы: