– 25 –
3) Precautions in bending
①
If it is necessary to bend or stretch the tubing,
use the spring which is attached to the tubing in
stead of pipe bender.
• Please make a careful notice to make a smooth
line.
• Hold the tubing with your two hands closely and
then bend or stretch it slowly not to make any
crack.
• Remember that the radius (R) should not exceed
70mm (Refer to Fig. 1)
②
Do not repeat the bending process to prevent the
tubing from cracking or crushing.
③
Keep in mind that the bending part should not be
cracked and make the radius (R) as long as possi-
ble (Refer to Fig. 2)
Spring
R70mm
(Fig. 1)
(Fig. 2)
R
6.4 Connecting Piping to Outdoor Unit
1) Connecting pipings to the outdoor unit
Upon connecting 4-way valves, please weld connecting pipes using elbows instead of connecting pipes with
flare nuts.
6.5 Connecting the Cable
①
Open the control board cover from the outdoor
unit by removing the screws.
②
Connect wires to the terminals on the control
board individually and secure the cables onto the
control board with clamp.
Содержание LP-10091CL/XL
Страница 1: ...Package Air Conditioner SERVICE MANUAL MODEL LP 10091CL XL LP 15091CL XL LP 20091CL XL ...
Страница 7: ...2 1 LP 10091CL XL 2 2 LP 15091CL XL 2 3 LP 20091CL XL 7 2 DIMENSIONS ...
Страница 53: ... 53 9 ELECTRONIC CONTROL DEVICE 9 1 MAIN P C B ASSY ...
Страница 55: ... 55 10 SCHEMATIC DIAGRAM LP 10091CL XL LP 15091CL XL ...
Страница 57: ... 57 22 19 10 4 5 1 12 21 20 15 13 16 2 9 8 7 18 17 6 3 11 14 ...
Страница 62: ... 62 3 13 12 9 11 10 2 8 1 6 5 7 4 16 17 24 25 22 20 14 15 23 21 26 19 ...
Страница 67: ... 67 3 13 12 9 11 10 2 8 1 6 5 7 4 16 17 24 25 22 20 14 15 23 21 26 19 ...
Страница 76: ...11 6 Outdoor Unit LP 20091CL 20091XL 1 Exploded View 76 ...
Страница 79: ...P No 3828A20023A May 2000 Printed in Korea ...