background image

– 7 –

STEP 1: PREPARE THE ELECTRICAL
CONNECTIONS

1. Locate the grounded electric outlet for this oven in the

cabinet above the oven, as shown in Figure 5.

NOTE:

The outlet should be on a circuit dedicated to the

microwave oven (120V, 60 Hz., AC only) with a 15 or 20A
fused electrical supply.

IMPORTANT:

If you do not have the proper wall outlet,

you MUST have one installed by a qualified electrician.

2. You will cut the power-supply-cord hole (shown in Figure 5)

later when you prepare the wall and upper cabinet in Step 4.

NOTE:

Do not use an extension cord.
Keep the power cord dry and do not pinch or crush it.

DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD
GROUNDING PRONG!

This appliance MUST be grounded!

Upper

Cabinet

Power-Supply-Cord Hole

Figure 5

Grounded Outlet

(Inside Cabinet)

Improper grounding could result in electric shock or other personal injury.

W A R N I N G

AVOID ELECTRICAL SHOCK! THIS APPLIANCE MUST BE GROUNDED!

W A R N I N G

Содержание LMVH1711STLG

Страница 1: ...P No 3828W5U0492 INSTALLATION INSTRUCTIONS MICROWAVE OVEN PLEASE READ AND SAVE THESE INSTALLATION INSTRUCTIONS www lg com ...

Страница 2: ...note where electrical outlets are and where electrical wires might be behind concealed in the wall YOU COULD RECEIVE AN ELECTRICAL SHOCK if you contact electrical wires with your drill bit Locate and disconnect the power of any electrical circuits that could be affected by installing this oven IF YOU DO NOT DISCONNECT THE POWER YOU RECEIVE AN ELECTRICAL SHOCK ELECTRICAL RATING OF THIS OVEN 120V AC...

Страница 3: ...o operate the microwave oven with the door open DO NOT tamper with or defeat the safety interlocks DO NOT place objects between the microwave oven front face and the door DO NOT allow soil or cleaner residue to build up on the flat surfaces around the microwave oven door DO NOT operate the microwave oven if it is damaged The microwave oven door must close properly to operate safely DO NOT USE THE ...

Страница 4: ...en away from strong draft areas such as windows doors and strong heating vents BE SURE you have enough space See Figure 4 below for minimum vertical and horizontal clearance CAUTION Before you begin installing the oven PLACE A PIECE OF THE CARTON OR OTHER HEAVY MATERIAL a blanket over the countertop or cooktop to protect it Do not use a plastic cover Failure to protect these surfaces could result ...

Страница 5: ... damper duct connector One power cord clamp bushing Actual Size for the cord hole in a metal upper cabinet NOTE You need to install at least two lag screws into a 2 x 4 stud and four anchor bolts into the wall and the mounting area must meet the 150 lbs weight requirement Four 1 4 x 2 lag screws Actual Size for wall stud holes Four 1 4 x 3 toggle bolts Actual Size for drywall holes Two 1 4 x 3 bol...

Страница 6: ...driver Measuring Tape Small Side Cutters or Tin Snips Gloves Keyhole Saw for the power cord hole 3 8 and 3 4 wood drill bits 1 2 and 3 16 drill bits Plumb Line Duct Tape Caulking Gun Electric Drill If you have brick or masonry walls you will need special hardware and tools The ductwork you need for the installation is not included All wall and roof caps must have a back draft damper Shown on page ...

Страница 7: ...lified electrician 2 You will cut the power supply cord hole shown in Figure 5 later when you prepare the wall and upper cabinet in Step 4 NOTE Do not use an extension cord Keep the power cord dry and do not pinch or crush it DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER SUPPLY CORD GROUNDING PRONG This appliance MUST be grounded Upper Cabinet Power Supply Cord Hole Figure 5 Grounded Outlet Insi...

Страница 8: ...rear exhaust method roof or wall venting be sure there is enough clearance within the wall for the exhaust duct REMEMBER AS YOU INSTALL THE VENTING Keep the length of the ductwork and the numberof elbows to a minimum to ventilate your oven efficiently See examples on page 9 Keep the size of the ductwork the same Do not install two elbows together Use duct tape to seal all joints in the duct system...

Страница 9: ... elbows and keep length as short as possible Below are the standard fittings and their equivalent length in feet To calculate the equivalent length of each duct piece used see the examples below Figure 10 6ft 2ft 2ft wall cap 6ft transition wall cap For 3 1 4 x10 SYSTEMS 1 3 1 4 x 10 90 elbow 25 ft 1 Wall Cap 40 ft 8 feet straight duct 8 ft TOTAL LENGTH 73 ft 1 transition 5 ft 2 90 elbows 20 ft 1 ...

Страница 10: ...ll 3 Locate exhaust adapter grease filters and hardware packet 4 At this point remove any adhesive tape if there is any on the exhaust adapter the grease filters and the power supply cord Room Vented recirculating Installation This oven is shipped assembled for room vented Wall Vented Installation 1 Remove one blower unit mounting screw and one or two blower plate screw s Remove the blower plate f...

Страница 11: ... Figure 15 5 Rotate the unit so that the exhaust ports face the rear of the cabinet See Figure 17 When you insert blower unit blower wire must be like figure 16 6 Place blower unit back into cabinet Check that the exhaust ports face towards the rear of the cabinet See Figure 17 7 Reattach the blower plate to cabinet so the exhaust ports and blower plate opening are aligned Attach with one blower u...

Страница 12: ...ng plate Make sure the minimum width is 30 inches and that the top of the mounting plate is located a minimum of 30 inches above the cooking surface See Figure 25 NOTE If the cabinets are not plumb adjust the mounting plate to the cabinets If the front edge of the cabinet is lower than the back edge adjust the mounting plate to be level with the cabinet front 5 Measure the bottom of the upper cabi...

Страница 13: ...h the power supply cord bushing supplied to prevent damage to the cord from the rough metal edge 4 Cut out the venting areas with the saber saw Roof Vented cut out the shaded area marked L on the upper cabinet template Wall Vented Tape the rear wall template to the rear wall lining up with the holes previously drilled for holes A and B in the plate Cut out the shaded area marked F on the REAR WALL...

Страница 14: ...t be secure Installer must use these holes for proper installation Use toggle bolts through these holes unless one of them lines up with a stud Use a wood screw for studs NOTE Draw a fifth circle inside area E through one of the bottom holes to match the location of a stud For wall vented The oven requires a rear wall cutout opening for the rear wall duct and the exhaust adapter must be attached t...

Страница 15: ...te to determine the location and size of the box cutout for the rear wall duct Attach the exhaust adapter to the rear mounting plate back plate wall side Push in securely until it is past the top locking tabs and in the lower locking tabs Take care to assure the damper hinge is installed so that it is at the top and that the damper swings freely Carefully guide the exhaust adapter now attached to ...

Страница 16: ...oven upward so the top of oven is against the bottom of the upper cabinet or cabinet frame 3 Then insert a bolt down through each hole in the upper cabinet bottom See Figure 33 Tighten the bolts until the gap between the upper cabinet and microwave oven is closed 4 If wall vented or room vented installation is used go to No 7 on the next page Figure 32 Figure 33 power cord power cord hole To avoid...

Страница 17: ...he power supply cord clamp using a screw as shown in Figure 35 to the inside of the cabinet 7 Grasp filter screen with one hand holding the ring and the other hand holding the opposite end Insert the end of the filter screen without ring into the opening and slide towards the side of the microwave oven Insert ring end of filter screen into the opening and slide entire screen towards the center of ...

Страница 18: ...MEMO ...

Страница 19: ......

Страница 20: ...Printed in Korea ...

Отзывы: