PRELIMINARY
A. SINCE NEARLY 2,100 VOLTS EXISTS IN SOME
CIRCUITS OF THIS UNIT REPAIRS SHOULD BE
CARRIED OUT WITH GREAT CARE.
The filament leads of magnetron carry High
Voltage with respect to ground. Extreme caution
must be exercised. Never plug the unit into a
power source to determine which component is
defective in high voltage section.
B. TO AVOID POSSIBLE EXPOSURE TO
MICROWAVE ENERGY LEAKAGE, THE
FOLLOWING PRECAUTIONS MUST BE TAKEN
BEFORE SERVICING.
(1) Before the power is applied:
(a) Make sure the primary interlock switch, the
secondary interlock switch and the interlock
monitor switch operate properly by opening
and closing the door several by opening and
closing the door several times.
(b) Make sure the perforated screen and the
dielectric choke of the door are correctly and
firmly mounted.
(2) After power is applied:
(a) Make sure the interlock switch mechanism
is operating properly by opening and closing
the door.
(b) Check microwave energy leakage must bebelow
the limit of 5 mW/cm
2.
(All service adjustments should be made for
minimum microwave energy leakage
readings).
(3) Do not operate the unit until it is completely
repaired, if any of the following conditions exist.
The unit must not be operated.
(a) The door does not close firmly.
(b) The hinge is broken.
(c) The door seal is damaged.
(d) The door is bent or warped, or there is any
other visible damage on the unit that may
cause microwave energy leakage.
NOTE:
Always keep the seal clean.
(e) Make sure that there are no defective parts
in the interlock mechanism.
(f) Make sure that there are no detective parts
in the microwave generating and transmission
assembly (especially waveguide).
(4) The following items should be checked after the
unit is repaired:
(a) The interlock monitor switch is connected
correctly and firmly.
(b) The magnetron gasket is properly positioned
and mounted.
(c) The waveguide and the oven cavity are intact.
(no microwave energy leakage)
(d) The door can be properly closed and the
safety switches work properly.
(e) The unit must stop when the door is opened or
the time is up.
The unit must not be operated with any of the above
components removed or by-passed.
7-1
PRECAUTIONS AND REPAIR SERVICE TIPS
SERVICE INFORMATION
Содержание LMV1925SB
Страница 9: ...5 1 SCHEMATIC DIAGRAM OVERALL CIRCUIT DIAGRAM ...
Страница 10: ...5 2 MATRIX CIRCUIT FOR TOUCH KEY BOARD CUSTOM SET CUSTOM COOK Q DEFROST Ez On ...
Страница 37: ...8 1 EXPLODED VIEW DOOR 13581A 13552A 13536A 13213A 14970A 14026A WTT028 13720D 14890A 13650A 14760A EV ...
Страница 38: ...8 2 CONTROL PANEL 24781M 24810P 23572A 07 268711 WTP013 WTT029 23506A EV ...
Страница 40: ...8 4 LATCH BOARD 466001 43501A 43500A 466003 466001 44510A WSZ084 EV ...
Страница 43: ...8 7 INSTALLATION WSZ133 44360A WSZ098 WWZ068 WWZ068 WBZZ02 56411A 65862D 63300M 63861A WBZZ01 WSZ136 65862B EV ...
Страница 44: ...8 14 SCHEMATIC DIAGRAM OF P C B ...
Страница 45: ...8 15 PRINTED CIRCUIT BOARD ...
Страница 46: ...P NO 3828W5S2345 June 2002 Printed in Korea ...