Date:
Job
Name/Location:
PO
No.:
Architect:
Engr:
GC:
Rep:
For:
File
Approval
Mech:
Resubmit
Other
Tag
#:
(Company)
(Project
Manager)
LMDN095HV
Flex
Multi
Ceiling
Concealed
Duct
Btu/h
Indoor
Unit
9,000
Performance:
Nominal
Capacity
(Btu/h)
9,000
Cooling
Nominal
Test
Conditions:
Heating
Nominal
Test
Conditions:
Indoor:
80°F
DB/67°F
WB
Indoor:
70°F
DB/60°F
WB
Outdoor: 95°F
DB/75°F
WB
Outdoor: 47°F
DB/43°F
WB
Electrical:
Power
Supply
(V¹/Hz/Ø)
208
Ͳ
230/60/1
Rated
Amps
(A)
0.25
Piping:
Liquid
Line
(in,
OD)
1/4
Vapor
Line
(in,
OD)
3/8
Features:
•2
Thermistor
control
•Auto
opera
Ɵ
on
•Auto
restart
•Control
lock
func
Ɵ
on
•Internal
Condensate
Pump
•Inverter
(variable
speed
fan)
Optional
Accessories
(sold
separately)
AC
Smart
II
Ͳ
PQCSW320A1E
ACP
without
DIgital
I/O
Ͳ
PQCPA11A03
ACP
with
Digital
I/O
Ͳ
PQCPB11A0E
LonWorks
Gateway
Ͳ
PQNFB16A1
BACnet
Gateway
Ͳ
PQNFB17B0
Drain
OD,
ID
(in)
1
Ͳ
1/4,
1
Temperature
Sensor
Thermistor
Max
Length
Each
Pipe
(ft)
82
Max
Elevation
between
ODU
and
IDU
(ft)
49.2
Max
Elevation
between
IDU
and
IDU
(ft)
24.6
Operating
Range:
Heating
Min
(°F
DB)
59
Unit
Data:
Refrigerant
Type
R410A
Refrigerant
Control
EEV
Sound
Pressure
H/M/L
(±3
dB(A))
32/26/25
Primary
Filter
Washable
Pre
Ͳ
filter
Net
Unit
Weight
(lbs)
46
Shipping
Weight
(lbs)
50
Communication
Cable
(No
x
AWG)
4
x
18
Fan:
Type
Sirocco
Quantity
3
Motor/Drive
Brushless
Digitally
Controlled/Direct
Airflow
Rate
H/M/L
(CFM)
300/265/229
Standard
Features:
•Limited
Warranty
with
LG
Cer
Ɵ
fi
ed
Installa
Ɵ
on
•Limited
Two
Year
Func
Ɵ
onal
Parts
Warranty
Dehumidification
Rate
(pts/h)
2.1
Notes:
1.Acceptable
opera
Ɵ
ng
voltage:
187V
Ͳ
253V.
2.See
Engineering
Manual
for
sensible
and
latent
capaci
Ɵ
es.
3.Sound
Pressure
levels
are
tested
in
an
anechoic
chamber
under
ISO
Standard
1996.
4.All
communica
Ɵ
on
cable
to
be
minimum
18
American
wire
gage
(AWG),
2
Ͳ
conductor,
stranded,
shielded
and
must
comply
with
applicable
local
and
national
code.
5.Power
wiring
cable
size
must
comply
with
the
applicable
local
and
na
Ɵ
onal
code.
6.This
unit
comes
with
a
dry
helium
charge.
7.This
data
is
rated
0
Ō
above
sea
level,
with
24.6
Ō
of
refrigerant
line
per
indoor
unit
and
a
0
ft
level
difference
between
outdoor
and
indoor
units.
All
capacities
are
net
with
a
combination
ratio
between
95
–
105%.
8.Must
follow
installa
Ɵ
on
instruc
Ɵ
ons
in
the
applicable
LG
installa
Ɵ
on
manual.
7
Ͳ
Day
Programmable
Controller
(Black)
Ͳ
PQRCVSL0
Simple
Controller
without
Mode
(Black)
PQRCHCA0Q
7
Ͳ
Day
Programmable
Controller
(White)
Ͳ
PQRCVSL0QW
Simple
Controller
without
Mode
(White)
Ͳ
PQRCHCA0QW
Included
Accessories:
•Simple
Controller
with
Mode
(White)
Ͳ
PQRCVCL0QW
PQRCVCL0QW
Max
External
Static
Pressure
(in
wg)
0.157
Page
1
of
2
DFS
Ͳ
SB
Ͳ
AD
Ͳ
008
Ͳ
US
012M17
For
continual
product
development,
LG
reserves
the
right
to
change
specifications
without
notice.
LG
Electronics
U.S.A.,
Inc.,
Englewood
Cliffs,
NJ.
All
rights
reserved.
“LG
Life’s
Good”
is
a
registered
trademark
of
LG
Corp.
/www.lghvac.com
Simple
Controller
with
Mode
(Black)
Ͳ
PQRCVCL0Q
AC
Ez
Ͳ
PQCSZ250S0
Dry
Contact
Unit
Dry
Contact
Unit
(1
contact,
24
VAC
external
power)
Ͳ
PQDSB1
Dry
Contact
Unit
Dry
Contact
Unit
(2
input,
power
from
indoor
unit)
Ͳ
PQDSBC
Dry
Contact
for
third
party
thermostat
Ͳ
PQDSBNGCM1
Cooling
Max
(°F
WB)
76