Copyright ⓒ 2019 LG Electronics. Inc. All right
reserved. Only training and service purposes
LGE Internal Use Only
Check TP1
VBAT is OK?
START
YES
The Problem may be Logic part
Refer to Logic trouble shoot
NO
Check TP2
0.5V ≤ TP2 ≤ 4.4V ?
Check U0704 Physical Damage
or soldering condition
NO
YES
TP1
3. TROUBLE SHOOTING
The PMIC(MT6357, U0704) output voltages is used as the reference one of RF Device
3.3 Checking DC-DC Block
Checking Flow
Image
TP2
Circuit Diagram
TP1
TP2
19