LG LG N1C-A3 Series Скачать руководство пользователя страница 6

6

Mechanical Installation

Module Mounting

• The LG Electronics’ (LGE) Limited Warranty for

solar modules is contingent upon modules being
mounted in accordance with the requirements
described in this section.

• Any module without a frame (laminate) shall not be

considered to comply with the requirements of UL
1703 unless the module with hardware that has
been tested and evaluated with the module under
this standard or by a field inspection certifying that
the installed module complies with the requirements
of UL 1703.

Site Consideration

LGE solar modules should be mounted in a location
that meets the following requirements.

Operating Temperature

• Maximum Operating Temperature: +90°C (194°F)

• Minimum Operating Temperature: -40°C (-40°F)

Design Strength

• LGE solar modules are certified to basic loads

50lb/ft2 (about 2400 Pa).

Excluded Operating Environments

• The solar modules from LG Electronics can not be

operated in a location where they could come in
direct contact with salt water or ammonia.

Electrical Installation

General Wiring

• LG Electronics recommends that all wiring be double

insulated with a minimum rating of 90°C (194°F).

• All wiring should use a flexible copper (Cu) conductor.

• The minimum size should be determined by the

applicable codes. 

• LG Electronics recommends a size no smaller than

12AWG.

Earth Grounding

• All work must be conducted in conformance with all

Federal, State, and local codes and standards.

• Grounding works should be performed by an

authorized installer for the safety and maintenance of
the system in accordance with all national, state and
local electrical codes and regulations and standards.

• Specific information on the solar module

dimensions and location of grounding holes is
provided in “Product Specifications”.

• One M4 stainless steel bolt, one nut, one spring

washer two flat washers one cup washer one star
washer and 12 AWG Cu wires are recommended
per mounting hole.

• Where common grounding hardware (nut, bolts,

washers) is used to attach a listed grounding
device, the attachment must be made in
conformance with the grounding device
manufacturer’s instructions.

• There is an earth hole on the edge of the module

frame Using this hole an earth conductor and the
solar module frame may be recommended to be
connected and earthed as the below drawing.

• All screws and nuts shall be tightened to a torque

of 4~5 Nm.

• A module with exposed conductive parts is

considered to be in compliance with UL 1703 only
when is electrically grounded in accordance with
the instructions presented below and the
requirements of the National Electrical Code.

The installation instructions shall include:

1. Details for wiring shall comply the NEC Article

690.

2. Details for the grounding method of the frame of

arrays shall comply with the NEC Article 250.

3. CNL model instruction manuals shall also include

a statement that installation shall be in
accordance with CSA C22.1, Safety Standard for
Electrical Installations, Canadian Electrical Code,
Part 1.

Module frame

Bolt

Flat washer

Star washer

Cup washer

Flat washer

Spring washer

Nut

Grounding
wire

Содержание LG N1C-A3 Series

Страница 1: ...N1C W K A3 LGXXXN1C W K B3 A minimum slope of 5 in ft for installation over a roof is required to maintain the fire class ratings The array frame shall be grounded in accordance with NEC Article 250 Installation Instructions MFL68783801 ...

Страница 2: ...iability Disposal 10 7 Transporting and Storage 10 8 Appendix 11 Date Version Remark Description of change 2013 08 13 2014 02 07 2014 09 24 2014 10 14 2014 10 20 2014 11 13 1 0 1st edition 2 0 3 0 4 0 5 0 6 0 Add B3 Model LGXXXN1X B3 Add 305 310W Power output Model Add Appendix Contents Edit to description of Mechanical Installation Edit to Electrical Properties Except K Model ...

Страница 3: ...ty gear Contact may result in lethal spark or electric shock Do not use or install if the module is broken or torn Failure to comply may result in electric shock Perform all work in dry conditions and use only dry tools Do not handle wet panels without appropriate protection equipment Failure to comply may result in accident or death accident or death Damaged modules must be treated with safety pr...

Страница 4: ... solar module After installation or repair check that the solar module are operating properly In the event that the currently used solar module or parts have been replaced the newly replaced module and parts must have the same model name and parts as the previously installed solar module Secure all necessary permits and licenses to install the solar modules Only qualified and authorized individual...

Страница 5: ...PV output Depending on national directives additional safety factors might be applicable for overcurrent protection The junction box should not be opened Opening the junction box will void the warranty Panels with a suspected electrical problem should be returned to LG Electronics for inspection and possible repair or replacement as per the warranty conditions provided by LG Electronics Electrical...

Страница 6: ...should be performed by an authorized installer for the safety and maintenance of the system in accordance with all national state and local electrical codes and regulations and standards Specific information on the solar module dimensions and location of grounding holes is provided in Product Specifications One M4 stainless steel bolt one nut one spring washer two flat washers one cup washer one s...

Страница 7: ...r from entering the junction box which could cause a safety hazard Clearance between the solar module frames and structures such as roofs or ground is required to prevent wiring damage and to allow air to circulate behind the solar module The recommended standoff height is a minimum of 100mm When installed on a roof the solar module must be mounted over a fire resistant roof covering rated for the...

Страница 8: ...frame and two clamps at the center of long Frame Clamping Range 230mm Use four clamps on the Short frame This method is not tested by IEC UL This installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop 2 Flat roof If installed with an additional stand such as wind shield or deflector Clamping Range From module Edge to 270mm Clamping Range From mod...

Страница 9: ...rcent Standard Test Condition STC Irradiation 1 000W m2 Cell temp 25 C 1 5AM Dimensions of Modules Note Relative efficiency reduction by respect to irradiance MC4 formal name PV KST4 6II UR PV KBT4 6II UR A safety locking clip MC PV SSH4 may be required per article 690 of NEC 2008 Note Holder is for the convenient connection of junction box cable but that does not warranty if it is broken after in...

Страница 10: ...ervice of LG Solar Modules and if applicable from all liabilities claim Solar Modules and if applicable from all liabilities claims demands losses or damages on my account caused or alleged to be caused in whole or in part by the negligence of the LG its affiliated companies successors or assigns its administrators directors agents officers volunteer and employees Disposal Please contact us if you...

Страница 11: ...amples of Rails and WEEBs are included in the following tables Torque 8 12Nm LG Model LGxxxS1C W K A3 LGxxxS1C W K B3 LGxxxN1C W K A3 LGxxxN1C W K B3 Rails and WEEBs Test sample for UL test UGC 1 Top Mounting UniRac Inc Grounding Clips No Rail Washer Clamp Compatibility UGC 1 UniRac 1 Solarmount Standard Solarmount Light Solarmount HD WEEB DMC UL file no QIMS2 E351343 IronRidge 2 Standard Rail XRS...

Страница 12: ...12 Appendix No Rail Washer Clamp Compatibility WEEB KMC Everest 3 CrossRail 48 CrossRail 38 WEEB PMC UL file no QIMS2 E351343 UL file no QIMS2 E351343 ProSolar 4 Rooftrac Groundtrac ...

Страница 13: ...ionally Important Notes 1 The NEC section 690 43 states Exposed non current carrying metal parts of module frame equipment and conductor enclosures shall be grounded in accordance with 250 134 or 250 136 A regardless of voltage 2 Use general purpose anti seize compound on fastener threads when installing WEEBs 3 WEEBs are intended for SINGLE USE ONLY Functionality will not be guaranteed if reused ...

Страница 14: ...om http www lgsolarusa com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws Document II A3 N UL V5 EN 201308 ...

Отзывы: