3. TECHNICAL BRIEF
ͽͶ͑ͺΟΥΖΣΟΒΝ͑ΆΤΖ͑ΟΝΪ
3. TECHNICAL BRIEF
3.2.8 Sysclock Switching
The PMU controls the rf_sysclk_en signal of the DCXO in the RF macro. During startup the PMU enables the
DCXO. After the system is running the DCXO is controlled by the SCU of the baseband by using the
vcxo_enable signal. This is handled by a dedicated logic in the PMU, see Figure 3.2.5. As long as
rf_sysclk_en_pmu, the output of the PMU state-machine is high, vcxo_enable controls the rf_sysclk_en
signal to the RF. If rf_sysclk_en_pmu is low, the DXCO is switched off, independent from vcxo_enable.
Figure 3.2.4 PMU, CGU and External Reset