- 56 -
Change the
PCB
Cube mode doesn't work
2
Check the voltage.
(while pushing the lever S/W)
Is voltage correct?
No
Yes
6
Explain to customer
1
Check the loose connection
LEVER S/W
Voltage [V]
CON2
4
th
pin ~
B(NEUTRAL)
Pushing
112~115V
Not
Pushing
0~2V
3
Check the voltage.
(while pushing the lever S/W)
Is voltage correct compared with
table?
No
Yes
LEVER S/W
Voltage [V]
CON1
12
th
pin ~
13
th
pin
Pushing
9~12V
Not
Pushing
0~2V
Change the
PCB
CON1
4
Check the resistance value.
Is Geared Motor resistance
31.1 ~ 42.1Ω?
No
Yes
Replace
Geared Motor
Resistance [Ω]
Geared Motor
31.1 ~ 42.1
5
Check the resistance value.
Is Dispenser Motor resistance
9.9 ~ 12.1Ω?
No
Yes
Replace
Dispenser Motor
Resistance [Ω]
Dispenser Motor
9.9 ~ 12.1
Geared Motor
Dispenser Motor
PIN12 PIN13
CON2
Содержание LFXS30786 Series
Страница 4: ... 4 2 PARTS IDENTIFICATION Ice Bin Icemaker Ice Compartment Door ...
Страница 7: ... 7 ...
Страница 25: ... 25 5 CIRCUIT DIAGRAM ...
Страница 26: ... 26 6 TROUBLESHOOTING ...
Страница 27: ... 27 ...
Страница 29: ... 29 7 3 Sub PCB ...
Страница 107: ... 107 13 DESCRIPTION OF FUNCTION CIRCUIT OF MICOM ...
Страница 108: ... 108 ...
Страница 118: ...P No MFL68488638 Nov 2015 Printed in Korea ...