![LG LFXS24623B Скачать руководство пользователя страница 80](http://html.mh-extra.com/html/lg/lfxs24623b/lfxs24623b_service-manual_1903273080.webp)
12. TROUBLESHOOTING
Month
1 : January
O : October
N : November
9 : September D : December
~
The information tag provides compressor model, refrigerant, serial number and safety approval
There are two types of controllers used in the linear compressor system.
- The “A”-inverter system is used with theFLB075L*NA compressor.
Name Plate
Compressor Label
12-1 INFORMATION OF LINEAR COMPRESSOR
FLB075LANA
Size : 90mm X 20mm
1. Compressor Model
2. Refrigerant
3. Serial Number
4. Safety Approval
Ex)
F L B 0 7 5 L * N A
00 00 9 2003 5 13 0012
Series name
DLF/FA/FB/FLA/FLB
Operating Type
A : A-Inverter
E : E-Inverter
Rated Voltage
& Frequency
- M : 220V 50/60Hz
- N : 115V 50/60Hz
Efficiency version
A : 1
st
generation
B : 2
nd
generation
Displacement
ex)90=9.0cm³ /stroke
Application Category
- L : LBP with R134a
- H : HBP with R134a
- N : LBP with R600a
Buyer Code
Model Code
Line
Serial No.
Date
Year
**CVCF : Constant Voltage Constant Frequency
FLB075L*NA
E-Inverter
System
Refrigerator
Comp Drive
Inverter
VVVF
Compressor
Stroke
Modulation
Controls the
algorithm
according to
various
conditions.
**CVCF : Variable Voltage Variable Frequency
Содержание LFXS24623B
Страница 1: ...REFRIGERATOR SERVICE MANUAL LFXS24623S LFXS24623W LFXS24623B ...
Страница 20: ...5 CIRCUIT DIAGRAM ...
Страница 22: ...7 PCB PICTURE 7 1 Main PCB P No MFG Picture EBR792671 2014 06 CON5 CON6 CON7 CON2 CON3 CON1 CON201 CON4 ...
Страница 85: ......
Страница 87: ......
Страница 88: ......
Страница 89: ......
Страница 102: ... EV 145C 145F 136D 132P 136A 131A 136B 136C 133A 133B FREEZER PARTS ...
Страница 105: ... EV 625A 623B 623B 616J 616J 627D 627B 627A 619A VALVE WATER TUBE PARTS ...
Страница 106: ... EV 630J 630J 600C 606A 600A 600B 630F 630A 630H 630G ICEMAKER BIN PARTS ...
Страница 107: ...Aug 2014 P No MFL62526051 ...