Change the
PCB
Cube mode doesn't work
2
Check the voltage.
(while pushing the lever S/W)
Is voltage correct?
No
Yes
6
Explain to customer
1
Check the loose connection
LEVER S/W
Voltage [V]
CON2
3
rd
pin ~ 12
th
pin
Pushing
112~115V
Not
Pushing
0~2V
3
Check the voltage.
(while pushing the lever S/W)
Is voltage correct compared with
table?
No
Yes
LEVER S/W
Voltage [V]
CON3 5
th
pin ~
CON1 13
th
pin
Pushing
9~12V
Not
Pushing
0~2V
Change the
PCB
4
Check the resistance value.
Is Geared Motor resistance
144~ 176
Ω
?
No
Yes
Replace
Geared Motor
Resistance [
Ω]
Geared Motor
31.1 ~ 42.1
5
Check the resistance value.
Is Dispenser Motor resistance
9.9 ~ 12.1
Ω
?
No
Yes
Replace
Geared Motor
Resistance [
Ω]
Dispenser Motor
9.9 ~ 12.1
Geared Motor
Dispenser Motor