- 25 -
0
Ω
OFF
Other
Short
Open
Normal
Change the sensor
Replace the refrigerator
Check the Temp and
resistance (Table-3)
Result
SVC Action
8-4 Defrost Sensor Error (F dS)
No
1
2
Checking flow
Check for a loose connection.
Check the Orange to Orange.
Result & SVC Action
Check the Brown to Brown at
CON7 on the main PCB
<CON7>
<Temperature table-3>
(1) To (2)
23°F
/ -5
°C
32°F
/ 0
°C
41°F
/ 5
°C
50°F
/ 10
°C
59°F
/ 15
°C
Result
38
㏀
30
㏀
24
㏀
19.5
㏀
16
㏀
※
The sensor is determined by
the temperature.
For example, 30
㏀
indicates 32°F.