- 40 -
9-8 Over cooling in Refrigerator room
No
1
Checking flow
Check the R Sensor resistance.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Open Refrigerator room door and Check
the air flow.
※
The R Sensor is determined by
the temperature.
For example, 30
kΩ
indicates 32°F.
Result & SVC Action
Status
Windy
No windy
SVC Action
Go to the 4
Check the R Fan Check
the damper (Go to the 5)
4
Input Test 2 Mode and
Check the air flow.
(push the button 1 more time)
Status
Windy
No windy
SVC Action
Go to the 5
It’s normal
5
Check the damper resistance.
<CON7>
Temperature
23°F
/ -5
°C
32°F
/ 0
°C
41°F
/ 5
°C
50°F
/ 10
°C
59°F
/ 15
°C
Result
38
30
24
19.5
16
(1)
(4)
(3)
(2)
(1) To (2)
(3) To (4)
270 ~ 330
Other
270 ~ 330Ω
Other
It’s normal
Change damper
It’s normal
Change damper
Result
SVC Action
Test
Point
kΩ
kΩ
kΩ
kΩ
kΩ
Ω