<Drawer Model>
<Swing Model>
0
Ω
OFF
Other
Short
Open
Normal
Change the sensor
Replace the refrigerator
Check the Temp and
resistance (Table-2)
Result
SVC Action
7-2 Refrigerator Sensor Error (rS E)
No
1
2
Checking flow
Check for loose connection in
.
CON7
Result & SVC Action
<Temperature table-2>
Temperature
23°F / -5°C
32°F / 0°C
41°F / 5°C
50°F / 10°C
59°F / 15°C
Result
38.5 ~ 36.5
㏀
30.5 ~ 29.5
㏀
24.5 ~ 23.5
㏀
20 ~ 19
㏀
16 ~15.5
㏀
※
The sensor is determined by
the temperature.
For example, 30
㏀
indicates 32°F.
1-. Unplug connector from CON7.
2-. Check resistance between
wires
.
White to White
17