8-2-5 Temperature Sensor Circuit
The upper circuit reads refrigerator temperature, freezer temperature, and defrost sensor temperature for defrosting and the
indoor temperature for compensating for the surrounding temperature into MICOM.
Opening or short state of each temperature sensor are as follows:
8-2-6 Refrigeration Compartment Stepping Motor Damper Circuit
* The circuit shown below is the damper circuit to regulate the refrigerator temperature.
- 32 -
SENSOR
CHECK POINT
NORMAL (-30°C ~ 50°C)
SHORT-CIRCUITED
OPEN
Freezer sensor
POINT Voltage
Refrigerator sensor
POINT Voltage
0.5 V ~ 4.5 V
0 V
5 V
Defrosting sensor
POINT Voltage
Room Temperature sensor
POINT Voltage
A
B
C
D