9-19
CHECKING FLOW CHART BY FAIRURE
Oven sensing error
→
→
F-1, F-2, F-4, F-5 error
1
Connect the power
Check the value of thermistor by using the test mode
• To enter the testmode, follow these steps:
1. press the “clear” key
2. press the “LOWER BAKE”,” LOWER BROIL” key at the same time for one second
3. press the “LOWER BAKE”,” LOWER BROIL” key at the same time again.
4. press the NUM “3” key
Normal : The sensor value is from 70°F to 90°F at 25°C.
UPPER SENSOR
LOWER SENSOR
Main oven sensing failed