- 27 -
7-3 RESISTANCE SPECIFICATION OF SENSOR
¥ Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB AS
SY, MAIN.
TEMPERATURE DETECTED
RESISTANCE OF FREEZER
RESISTANCE OF REFRIGERATOR &
BY SENSOR
SENSOR
DEFROST SENSOR & ROOM SENSOR
- 20 C
22.3 K
77 K
- 15 C
16.9 K
60 K
- 10 C
13.0 K
47.3 K
- 5 C
10.1 K
38.4 K
0 C
7.8 K
30 K
+ 5 C
6.2 K
24.1 K
+ 10 C
4.9 K
19.5 K
+ 15 C
3.9 K
15.9 K
+ 20 C
3.1 K
13 K
+ 25 C
2.5 K
11 K
+ 30 C
2.0 K
8.9 K
+ 40 C
1.4 K
6.2 K
+ 50 C
0.8 K
4.3 K
°
°
°
°
°
°
°
°
°
°
°
°
°
The resistance of the SENSOR has a ±5% common difference.
Measure the resistance of the SENSOR after leaving it for over 3 minutes in the measuring temperature.
This delay is necessary due to sensor response speed.