22
Multi F Ceiling Cassette Indoor Unit
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
MAX
MULTI
F
MULTI
F
Figure 18: Liquidtight 3/4 Inch
Elbow Connector Attached to
Flexible Conduit.
Vinyl tape (narrow)
Connection pipe
Connecting cable
Vinyl tape (wide)
Wrap with vinyl tape
Indoor unit pipe
Pipe
Bundling
If a conduit or piping set cover is not used on the connection from the outdoor unit to the
interior, bundle both separately insulated refrigerant pipes, the drain hose, and outdoor
unit to indoor unit communication / connection (power) cable together with wide vinyl
tape.
1. Both piping must be fully and separately encased in insulation material: Overlap the
field installation piping insulation material and the indoor unit piping insulation mate-
rial.
2. Bind together the two pipes, using vinyl tape. Make sure there are no gaps during the
binding. Verify that any insulation material cutting lines are placed upward.
3. Bind together the two pipes, using narrow vinyl tape. Make sure there are no gaps
during the binding.
4. Continue to wrap the indoor unit pipe as connected to the outdoor connection pipe.
5. Using a wider vinyl tape, bundle the piping and drain hose together.
• Tape must be sufficient to cover the piping in order to fit into the rear piping housing
area at the back of the indoor units.
Indoor Unit Connections
INSTALLATION
Using a Conduit for Indoor Unit Wiring / Cable Installation
8VHDOLTXLGWLJKWLQFKHOERZFRQQHFWRUIRUÀH[LEOHFRQGXLWWRSURWHFWWKHFRPPXQLFDWLRQFRQQHFWLRQ
SRZHUFDEOH
1. Indoor unit includes a conduit bracket that can be found in the accessory kit. Assemble the conduit and
bracket with a grommet and washer (field-supplied or included with the elbow connector).
2. Guide communication / connection (power) cable insulation into the conduit.
3. Attach the conduit / bracket assembly to the indoor unit using the screws found in the accessory kit.
•
&KHFNORFDOVWDWHDQGIHGHUDOFRGHVZKHQFKRRVLQJDFRQGXLWVL]H
•
)RUV\VWHPVZLWKZLULQJJUHDWHUWKDQIHHWVHHWKH³&RPPXQLFDWLRQ&RQQHFWLRQ3RZHU&DEOH6SHFLILFDWLRQVIURP
2XWGRRU8QLWWR,QGRRU8QLW´LQWKH(OHFWULFDO6\VWHP,QVWDOODWLRQVHFWLRQIRULQIRUPDWLRQ
4. To protect the piping, condensate drain, and conduit from the elements, add a lineset cover from the indoor access hole to the outdoor
unit.
Figure 19: Bundling the Connection Components
(From Outdoor Unit to Indoor Unit).
•
,IDFRQGXLWLVQRWXVHGVHHEHORZIRUEXQGOLQJLQIRUPDWLRQ
•
,IWKHGLVWDQFHEHWZHHQWKHRXWGRRUXQLWDQGLQGRRUXQLWLVJUHDWHUWKDQIHHWFRQQHFWWKHSRZHUZLULQJDQGFRPPXQLFDWLRQVFDEOHVHSD
-
UDWHO\LHDFRQGXLWFDQQRWEHXVHG
•
$OZD\VLQFOXGHLQVXODWLRQRQDOOUHIULJHUDQWDQGGUDLQKRVHWRHQVXUHFRQGHQVDWHGRHV
QRWIRUPDQGFDXVHGDPDJHWRZDOOVIORRUVHWF
•
3RVLWLRQLQJWKHGUDLQKRVHDWWKHWRSRIWKHEXQGOHFDQFDXVHFRQGHQVDWHWRRYHUIORZ
IURPWKHGUDLQSDQLQWKHLQVLGHRIWKHLQGRRUXQLW
•
)RUV\VWHPVZLWKZLULQJJUHDWHUWKDQIHHWVHHWKH(OHFWULFDO6\VWHP,QVWDOODWLRQ
VHFWLRQIRULQIRUPDWLRQ
Cut Line at Top
Piping
Connection
Cable
Tape
Drain Hose
Figure 20: Cut Line Position.
Figure 21: Cutaway of Proper Pipe and Cable
Bundling.