Connecting Cables between Indoor Unit and Outdoor Unit
Installation Manual
23
The power cord
connected to the outdoor unit should be
complied with the following specifications (Rubber
insulation, type H05RN-F approved by HAR or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly availible from the manufacturer of its service agent.
The connecting cable
connected to the indoor and outdoor
unit should be complied with the following specifications
(Rubber insulation, type H05RN-F approved by HAR or SAA).
CAUTION
20mm
GN/YL
20mm
GN/YL
NORMALCROSS-SECTIONA AREA 0.75mm
2
(30/36/42k)
1.25mm
2
(48/60k)
NORMAL CROSS-SECTIONAL AREA
Capacity
30k Btu/h
36k Btu/h
42k Btu/h
48k Btu/h
60k Btu/h
1 Phase
5.5mm
2
5.5mm
2
3 Phase
-
2.5mm
2
2.5mm
2
3.5mm
2
3.5mm
2
-
-
-
20mm
GN/YL
20mm
GN/YL
1 Phase(1P)
3 Phase(3P4W)
Cooling Only
Heat Pump
CAUTION: Make sure that the screws of the terminal fixed tightly.