8-1 FUNCTION
8-1-1 Function
1. When the appliance is plugged in, it is set to "4" for Refrigerator and "4" for freezer.
You can adjust the Refrigerator and the Freezer control temperature by pressing the ADJUST button.
2. When the power is initially applied or restored after a power failure, it is automatically set to "4" & "4".
8-1-2 Control of freezer fan motor
1. Freezer fan motor has high and standard RPMs.
2. High RPM is used when electricity is first on, for EXPRESS FREEZING , and when refrigerator is overloaded.
But standard RPM is used for general purposes.
3. To improve cooling speed and load corresponding speed, the RPM of freezer fan motor shall change from normal speed
to hign speed.
4. High speed (2500RPM) : Initial power on or load corresponding operation, EXPRESS FREEZING.
Normal speed ( 2200 RPM): general working conditions.
5. Fan motor stops when refrigerator of freezer door opens.
8-1-3 EXPRESS FREEZING
1. The purpose of this function is to intensify the cooling speed of freezer and to increase the amount of ice.
2. Whenever selection switch is pressed, selection/release, the LED will turn ON or OFF.
3. If there is a power cut and the refrigerator is power on again, EXPRESS FREEZING function will be canceled.
4.To activate these function you need to press the EXPRESS FREEZING key and the LED will turn ON. This function will remain
activated for 24 hrs. The first three hours the compressor and EXPRESS FREEZING will be ON. The next 21hours the freezer will
be controlled at the lowest temperature. After 24 hours or if the EXPRESS FREEZING key is pressed again, the freezer will
return to its previous temperature.
5. For the first three hours notice the following cases:
(1) Compressor and freezer fan(HIGH RPM) continuously operate for three hours.
(2) If defrost starts during EXPRESS FREEZING, EXPRESS FREEZING operates for the rest of time after defrost is
completed, when EXPRESS FREEZING operation time is less than 90 minutes.
If EXPRESS FREEZING operates for more than 90minutes, the EXPRESS FREEZING will operate for two hours after
defrost is completed.
(3) If EXPRESS FREEZING is pressed during defrost, EXPRESS FREEZING is on but this function will start seven
minutes after defrost is completed and it shall operate for three hours.
(4) If EXPRESS FREEZING is selected within seven minutes after compressor has stopped, the compressor (compressor
delays seven minutes) shall start after the balance of the delay time.
(5) The fan motor in the freezer compartment rotates at high speed during EXPRESS FREEZING.
6. For the rest of 21 hours, the freezer will be controlled at the lowest temperature.
8-1-4. REFRIGERATOR LAMP AUTO OFF
1. To protect the risk of lamp heat, when Refrigerator door opens for 7 min., refrigerator lamp is auto off.
8. DESCRIPTION OF FUNCTION & CIRCUIT OF MICOM
- 20 -
ADJUST
WARMER
REFRIGERATOR TEMP
FREEZER TEMP
4 IS RECOMMENDED
COLDER
EXPRESS
FREEZING
ADJUST
WARMER
4 IS RECOMMENDED
COLDER
Содержание LB Series
Страница 9: ...5 CIRCUIT DIAGRAM 9 ...
Страница 35: ...9 5 MAIN PWB ASSEMBLY AND PARTS LIST 9 5 1 Main PWB Assembly 35 ...
Страница 36: ...9 5 2 Replacement Parts List 36 ...
Страница 37: ...10 5 3 PWB Assembly Display and Parts List 37 ...
Страница 41: ...125A FREEZER PARTS CAUTION Use the part number to order part not the position number 131A 149A 136C 282X 41 EV ...
Страница 47: ... 3828JL 8799A MARCH 13TH 2006 ...