background image

–47–

Parts List

• 42K/48K/60K

152302

FILTER(MECH), A/C

5230A30001F 5230A30001A 5230A30001A 5230A30001A 5230A30001A

R

237204-1

PANEL, SIDE

3720A20067Y 3720A20010X 3720A20010X 3720A20010X 3720A20010X

R

237204-2

PANEL, SIDE

3720A20068Y 3720A20011X 3720A20011X 3720A20011X 3720A20011X

R

249951

CONTROL BOX ASSY, INDOOR 4995A20011S 4995A20011S 4995A20011T 4995A20011S 4995A20011T

R

263230-1

THERMISTOR ASSY

6323AQ3214Q 6323AQ3214Q 6323AQ3214Q 6323AQ3214Q 6323AQ3214Q

R

263230-2

THERMISTOR ASSY

6323AQ3226G 6323AQ3226G 6323AQ3226G 6323AQ3226G 6323AQ3226G

R

267110-1

REMOTE CONTROLLER ASSY 6711A10002D 6711A10002D 6711A10002C 6711A10002D 6711A10002C

R

267110-2

REMOTE CONTROLLER ASSY

6711A20041E 6711A20041E 6711A20041D 6711A20041E 6711A20041D

R

268714

PWB(PCB) ASSY, MAIN

6871A10008C 6871A10008C 6871A10008D 6871A10008C 6871A10008D

R

330860

DRAIN PAN

3086A30001K 3086A30001H 3086A30001H 3086A30001H 3086A30001H

R

336610-1

HOUSING ASSY(MECH)

3661A10009C 3661A10009E 3661A10009E 3661A10009E 3661A10009E

R

336610-2

HOUSING ASSY(MECH)

3661A10009D 3661A10009F 3661A10009F 3661A10009F 3661A10009F

R

346810

MOTOR ASSY, INDOOR

4681A20005M 4681A20005K 4681A20005K 4681A20005Q 4681A20005Q

R

4681A20005X 4681A20005U 4681A20005U 4681A20005V 4681A20005V

R

35211C-1

TUBE ASSY, DISCHARGE

5211A30077A 5211A30077A 5211A30077A 5211A30077A 5211A30077A

R

35211C-2

TUBE ASSY, DISCHARGE

5211A30094B 5211A30094B 5211A30094B 5211A30094B 5211A30094B

R

352118

TUBE ASSY, MANIFOLD(INDOOR)

5211A30093C 5211A30076A 5211A30076A 5211A30076A 5211A30076A

R

354210

EVAPORATOR ASSY

5421A20008F 5421A20008A 5421A20008A 5421A20008E 5421A20008E

R

359012-1

FAN ASSY, BLOWER

5901A10015C 5901A20015E 5901A20015E 5901A20015E 5901A20015E

R

359012-2

FAN ASSY, BLOWER

5901A10015D 5901A20015F 5901A20015F 5901A20015F 5901A20015F

R

552111

TUBE ASSY, CAPILLARY

5211A30123T 5211A30123M 5211A30123L 5211A30123N 5211A30123N

R

W0CZZ

CAPACITOR, DRAWING

2H00841C

0CZZA20001C 0CZZA20001C 0CZZA20001B 0CZZA20001B

R

2A00986D

2A00986D

2A00986D

2A00986D

LB-F4261HL

LB-E4881HL LB-E4881CL

LB-E6081HL LB-E6081CL

LB-F4263HL

LB-E4883HL LB-E4883CL

LB-E6083HL LB-E6083CL

LOCATION No.

DESCRIPTION

Part No.

REMARKS

Содержание LB-D1861CL

Страница 1: ... SERVICE MANUAL MODELS LB D1861HL CL LB D1863HL CL LB D2461HL CL LB D2463HL CL LB F3061HL LB F3063HL LB F3661HL CL LB F3663HL CL LB F3681HL CL LB F3683HL CL LB F4261HL LB F4263HL LB E4881HL CL LB E4883HL CL LB E6081HL CL LB E6083HL CL ...

Страница 2: ...ons 9 Refrigeration Cycle Diagram 11 Wiring Diagram 13 Operation Details 19 Installation of Indoor Outdoor Unit 22 Cycle 36 Cycle Troubleshooting Guide 39 Electronic Parts Troubleshooting Guide 40 Electronic Control Device 43 Exploded View and Replacement Parts List 44 2 ...

Страница 3: ...nction Group Control Optional Wiring Each controller can control 16 units and 8 controllers can connect It operates maximum 16 units by only one wired remote con troller and each unit starts random to prevent overcurrent Room temperature sensor Thermistor Maintains the room temperature in accordance with the Setting Temp Indoor fan is delayed for 5 seconds at the starting Restarting is inhibited f...

Страница 4: ...m Cooling model only Heating model only Low Med High Cooling Operation Mode Heating Operation Mode Auto Operation Mode Soft Dry Operation Mode Fan Operation Mode HI AUTO MED LO Program Holiday SET CLR Min Hour Week Timer Cancel Timer Cancel High 39 C LOW 11 C Fan Operates without cooling heating Cooling Heating Down to 18 C Up to 30 C Down to 16 C Up to 30 C ...

Страница 5: ...0 50 1 220 240 50 1 220 240 50 1 220 240 50 96 96 96 96 1 425 1 354 1 284 1 425 1 354 1 284 1 425 1 354 1 284 1 425 1 354 1 284 1 425 1 354 1 284 1 425 1 354 1 284 800 800 800 800 16 5 14 12 16 5 14 12 16 5 14 12 16 5 14 12 49 49 49 49 8 80 8 80 8 80 8 80 2 00 2 00 2 50 2 50 36 34 32 36 34 32 36 34 32 36 34 32 55 55 55 55 22 6 25 4 22 6 25 4 22 6 25 4 22 6 25 4 0 89 1 0 89 1 0 89 1 0 89 1 3 2 5 3 ...

Страница 6: ... 50 1 380 415 50 96 96 96 91 1 330 1 276 1 213 1 330 1 276 1 213 1 330 1 276 1 213 1 330 1 276 1 213 1 330 1 276 1 213 1 330 1 276 1 213 930 940 940 940 31 5 29 25 31 5 29 25 31 5 29 25 31 5 29 25 49 52 52 52 10 100 10 100 10 100 10 100 3 50 4 50 4 50 4 50 42 40 38 42 40 38 42 40 38 42 40 38 56 56 56 56 22 6 25 4 22 6 25 4 22 6 25 4 22 6 25 4 0 89 1 0 89 1 0 89 1 0 89 1 3 3 5 3 5 5 3 5 5 4 2 5 5 0...

Страница 7: ...mensions WXHXD Indoor mm inch Outdoor mm inch Net Weight indoor kg lbs Outdoor kg lbs Stuffing Quantity With Without S Parts 20 40ft LB F3681HL F3683HL LB F4261HL F4263HL 9 072 10 548 10 584 12 306 36000 42000 9 072 10 548 10 584 12 306 36000 42000 4 000 3 400 4 800 4 600 8 7 24 23 45 45 125 125 2 39 2 78 2 32 2 70 9 5 9 2 2 84 3 3 2 41 2 8 11 26 9 56 1 380 415 50 1 220 240 50 91 96 1 330 1 276 1 ...

Страница 8: ...80 415 50 90 90 90 90 1 034 976 932 1 034 976 932 1 151 1 075 1 030 1 151 1 075 1 030 1 034 976 932 1 151 1 075 1 030 880 880 880 880 40 35 31 40 35 31 46 40 35 46 40 35 105 105 105 105 10 15 100 150 10 15 100 150 10 15 100 150 10 15 100 150 6 00 6 00 6 50 6 50 42 40 38 42 40 38 45 43 41 45 43 41 62 62 62 62 22 6 25 4 22 6 25 4 22 6 25 4 22 6 25 4 0 89 1 0 89 1 0 89 1 0 89 1 3 3 5 3 3 5 3 3 5 3 3 ...

Страница 9: ...Dimensions 9 W D H 1 Indoor Unit MODEL DIM W mm 880 880 1180 1180 1180 1230 1230 H mm 281 281 298 298 298 370 370 D mm 575 575 600 600 600 680 680 18K 24K 30K 36K 42K 48K 60K ...

Страница 10: ... 2 Outdoor Unit 10 W H D W H D 36K 42K 48K 60K 18K 24K 30K MODEL DIM W mm 870 870 870 790 900 900 900 H mm 655 655 800 965 1 220 1 220 1 220 D mm 320 320 320 320 370 370 370 18K 24K 30K 36K 42K 48K 60K ...

Страница 11: ...tance of 15m 188g of refrigerant should be added 15 7 5 x25g 188g 11 INDOOR UNIT OUTDOOR UNIT HEAT EXCHANGER HEAT EXCHANGER COMPRESSOR GAS SIDE LIQUID SIDE COOLING HEATING REVERSING VALVE CAPILLARY TUBE Pipe size Diameter ø Piping length m Elevation m MODEL Gas Liquid Rated Max Rated Max 18K 5 8 1 4 7 5 50 5 30 25 24K 5 8 1 4 7 5 50 5 30 30 30K 5 8 3 8 7 5 50 5 30 50 36K 5 8 3 8 7 5 50 5 30 40 42K...

Страница 12: ...istance of 15m 188g of refrigerant should be added 15 7 5 x25g 188g INDOOR UNIT OUTDOOR UNIT HEAT EXCHANGER CONDENSER HEAT EXCHANGER CONDENSER COMPRESSOR GAS SIDE LIQUID SIDE CAPILLARY TUBE Pipe size Diameter ø Piping length m Elevation m MODEL Gas Liquid Rated Max Rated Max 18K 5 8 1 4 7 5 50 5 30 25 24K 5 8 1 4 7 5 50 5 30 25 36K 5 8 3 8 7 5 50 5 30 40 48K 3 4 3 8 7 5 50 5 30 50 60K 3 4 1 2 7 5 ...

Страница 13: ... BL BL RD BK YL BL BL BK GN YL GN YL COMP 4 WAY OUT FAN FUSE 250V10A TEMP THERMISTOR PIPE THERMISTOR FLOAT S W REMOTE CONTROL ZONE CONTROL OPTION TERMINAL BLOCK 7 3 L 4 N 5 6 TO OUTDOOR UNIT OUTDOOR WIRING DIAGRAM INDOOR WIRING DIAGRAM COMP R S H 4 2 8 6 1 0 C F BL YL OR BK TB2 BR BR BR BR BL BL BL BL BL GN YL GN YL YL RD CAPACITOR RD C POWER RELAY FAN MOTOR FUSE 5A FUSE 5A POWER INPUT TO INDOOR U...

Страница 14: ...S SWITCH DEICER PCB BR BL POWER INPUT TO INDOOR UNIT TERMINAL BLOCK TERMINAL BLOCK 1 2 FUSE 5A FUSE 5A POWER RELAY REVERSING VALVE COMP CAPACITOR YL OR OR BK BK BK BK WH YL FAN MOTOR INDOOR MOTOR DRAIN PUMP BR BR YL OR RD BL BL RD BK BL BL BK GN YL GN YL COMP 4 WAY FUSE 250V10A TEMP THERMISTOR PIPE THERMISTOR FLOAT S W REMOTE CONTROL ZONE CONTROL OPTION TERMINAL BLOCK 7 3 L 4 N 5 6 TO OUTDOOR UNIT...

Страница 15: ...K GN YL YL OR RD BL BL BL BK GN YL COMP 4 WAY FUSE 250V10A ROOM THERMISTOR PIPE THERMISTOR FLOAT S W REMOTE CONTROL ZONE CONTROL OPTIONAL EXTRA TERMINAL BLOCK TO OUTDOOR UNIT 3854A20031X 3 L 4 N 5 6 7 OUTDOOR WIRING DIAGRAM INDOOR WIRING DIAGRAM 3854A20025J INDOOR MOTOR DRAIN PUMP BR BR YL OR RD BL BL RD BL BL BK GN YL GN YL COMP FUSE 250V10A TEMP THERMISTOR PIPE THERMISTOR FLOAT S W REMOTE CONTRO...

Страница 16: ... RD GN YL BL BK WH T B1 F1 BK WH WH RD BK WH BK BK RD WH T1 T3 T2 CH1 Co OR YL Co OR FMo1 FMo2 CM YL YL BK BK BR BK BL BK WH GN YL TMo To the indoor unit WH 2 3 4 R S T N 20SV BK BK BK BK 1 2 3 4 5 6 OUTDOOR WIRING DIAGRAM INDOOR WIRING DIAGRAM 1 TM 3ø 380V 50Hz POWER SUPPLY BK 52C 1 3 5 31 2 4 6 32 B A BK WH WH BK WH BL GN YL T B F1 BK WH RD WH BK RD WH T1 T3 T2 Co OR YL Co OR FMo1 3854A90010Y FM...

Страница 17: ...ROL ZONE CONTROL OPTIONAL EXTRA TERMINAL BLOCK TO OUTDOOR UNIT 3854A20031X 3 L 4 N 5 6 7 CM 1 2 3 4 5 6 220 240V 1ø 50Hz POWER SUPPLY L N 1 2 3 4 5 6 31 32 B A WH BR BR RD BK YL YL YL FMo1 49FMo FMo2 49FMo Co TM 52C 63H2 Co BK YL BK OR OR RD BK BK RD Cr CH S R C WH WH WH BK BK BK WH WH WH BL YL BK RD RD To the indoor unit 52F1 BL WH PTCR GN YL GN YL Tmo 1 2 3 4 5 6 7 8 F1 T B1 T B2 BK BK BK BR OR ...

Страница 18: ...WH YL BK RD Fuse 250V 5A Fuse 250V 5A INDOOR MOTOR DRAIN PUMP BR BR YL OR RD BL BL RD BK BL BL BK GN YL GN YL COMP 4 WAY FUSE 250V10A TEMP THERMISTOR PIPE THERMISTOR FLOAT S W REMOTE CONTROL ZONE CONTROL OPTION TERMINAL BLOCK 1 L 2 N 4 3 5 TO OUTDOOR UNIT OUTDOOR WIRING DIAGRAM INDOOR WIRING DIAGRAM TO OUTDOOR UNIT INDOOR MOTOR DRAIN PUMP BR BR YL OR RD BL BL RD BL BL BK GN YL GN YL COMP FUSE 250V...

Страница 19: ... 3 5 seconds to switch 2 Soft Dry Operation The indoor fan speed is automatically set to the low so the shift of the indoor fan speed is impossible because of already being set to the best speed for Dry Operation by Micom Control 3 Cooling Mode Operation When selecting the Cooling Mode Operation the unit will operate according to the setting by the remote con troller and the operation diagram is a...

Страница 20: ...n speed when it becomes lower than 39 C the fan operates at low speed 4 Heating Mode Operation Except Cooling Model The unit will operate according to the setting by the remote controller and the operation diagram is shown as following Hot Start Low Selecting Fan Speed minimum 3min Selecting fan speed minimum 10sec 1min A A minimum 10sec B 5 Hot Start Control The indoor fan stops until the evapora...

Страница 21: ... 45 min later T2 since heating mode operation started are measured then defrost control is carried out according to the dirrerence T T1 T2 3rd priority Defrost control is carried out according to the temp dirrerence E TE1 TE2 between the indoor pipe temperatures of 25 min later TE1 and 45 min later TE2 after heating mode operation started When the indoor pipe temp is 41 C or above defrost control ...

Страница 22: ... heat radiation from the condenser is not restricted There should not be any animals or plants which could be affected by hot air discharged Ensure the spaces indicated by arrows from the wall ceiling fence or other obstacles 3 Piping length and the elevation Indoor unit Outdoor unit B A More than 30cm More than 30cm More than 70cm Sunroof Fence or obstacles Top view unit mm H Front view 600 600 F...

Страница 23: ... 54 600 30 87 830 186 1292 1230 570 5 54 680 30 120 1006 294 1292 1230 570 5 54 680 30 120 1006 294 Dimension Capacity 36K BTU h LB F36 42K BTU h 48K BTU h LB E48 60K BTU h LB E60 NOTE Throughly study the following installation locations 1 In such places as restaurants and kitchens considerable amount of oil steam and flour adhere to the fan the fin of the heat exchanger resulting in heat exchange...

Страница 24: ...n after receiving customer approval The room temperature sensor is built in the indoor unit This remote controller equipped with liquid crystal display If this position is higher or lower display is difficult to see The standard height is 1 2 1 5m high Routing of the remote controller cord Keep the remote controller cord away from the refrigerant piping and the drain piping To protect the remote c...

Страница 25: ...mps on the wall by ø 3 tapping screws accessory Fix the remote control cord WIRED REMOTE CONTROL INSTALLATION REMOTE CONTROL PREPARATION OPTIONAL DISASSEMBLING ELECTRICAL WIRING HOW TO MOUNT ONTO A WALL HOW TO INSERT BATTERIES Wire and make sure that teminal numbers are matched on unit side and remote controller side The maximum length of the cord is 100m If the length of the cord exceeds 50m use ...

Страница 26: ...erminals on the indoor unit 1 L 2 N 4 N 5 3 L Terminals on the outdoor unit 4 N 5 6 3 L 1 L 2 N 4 N 5 6 7 8 3 L 4 N 5 6 7 3 L Terminals on the indoor unit 1 2 4 5 3 Cooling Heating type Terminals on the indoor unit Terminals on the outdoor unit Terminals on the outdoor unit 1 2 4 5 3 1 L 2 N POWER INPUT R S T N The power cord connected to the outdoor unit should be complied with the following spec...

Страница 27: ...equired by the air conditioner Use a recognized circuit breaker between the power source and the unit A disconnection device to adequately disconnect all supply lines must be fitted Capacity of circuit breaker INDOOR UNIT Remove the control box cover for elec trical connection between the indoor and outdoor unit Remove two screws Use the cord clamper to fix the cord WIRING CONNECTION OUTDOOR UNIT ...

Страница 28: ...ely remove all burrs from the cut cross section of pipe tube Put the end of the copper tube pipe to downward direc tion as you remove burrs in order to avoid to let burrs drop in the tubing 3 Putting nut on Remove flare nuts attached to indoor and outdoor units than put them on pipe tube having completed burr removal Not possible to put them on after flaring work 4 Flaring work Carry out flaring w...

Страница 29: ...indoor and outdoor connection After completing the piping connection execute vacuum drying for the connecting piping and the indoor unit The vacuum drying must be carried out using the ser vice ports of both the liquid and gas side valves Use two wrenches and tighten with regular torque Outdoor unit Liquid side Flare connection Flare connection Gas side Indoor unit Union Flare nut fastening torque...

Страница 30: ...d inclination 1 50 to 1 100 Prevent any upward flow or reverse flow in any part 5mm or thicker formed thermal insulator shall always be provided for the drain pipe 1 Install declination of the indoor unit is very important for the drain of the duct type air conditioner 2 Minimum thickness of the insulation for the connecting pipe shall be 5mm The unit must be horizontal or declined to the drain ho...

Страница 31: ...HERMAL INSULATION 5 7mm Indoor Outdoor WALL Make sure that there is no clearance here Overlap with thermal insulator for piping Thermal insulator for refrigerant pipe Local supply Thermal insulator for piping Local supply Hose crip for thermal insulator Local supply Union for liquid pipe Refrigerant pipe and thermal insulator Local supply Union for gas pipe Thermal insulator for refrigerant pipe L...

Страница 32: ...rature checking button and down timer button for 3 sec onds at the same time To cancel the test run press any button After completing work be sure to measure and record trial run properties and store measured data etc Measuring items are room temperature outside temperature suction temperature blow out temperature wind velocity wind volume voltage current presence of abnormal vibration and noise o...

Страница 33: ...ed on the name plate 7 Confirm that the cable thickness is as specified in the power sources specification Particularly note the relation between cable length and thickness 8 Never fail to equip a leakage breaker where it is wet or moist 9 The following troubles would be caused by voltage drop down Vibration of a magnetic switch damage on the contact point there of fuse breaking disturbance to the...

Страница 34: ... temperature of main body and of remote controller sensor 3 Move the slide switch to set position 4 Close the rear cover and check if it works normally TH R14H SW TH REMO MAIN 2TH OP7 R18H R17H OP6 LO STAND SW HIGH HI R03S C070 R04S R02S R01S OP3 OP2 OP1 R19H R11H R13H R12H OP5R16H OP4 R15H CO1H REMO Room Temp sensor 2TH MAIN Position 2 Position 1 Position 3 Slide switch for 2Thermistor Select the...

Страница 35: ...WING OPERATION FAN SPEED Program set SUB FUNCTION SET TEMP Room Temp HI MED LO Heater Defrost Filter Preheat Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 Indoor Unit 1 Terminal Local Supply Block Terminal Local Supply Block Terminal Local Supply Block Main PCB 1 Main PCB 2 Main PCB 16 Wired Remote Controller Slide Switch OP7 Remote Controller PCB Indoor Unit 2 Main PC...

Страница 36: ...ce port must be closed this test is only for checking whether pipe connection is ok or not 5 If there is no leakage discharge R22 in piping completely into tank for retrieving Complete discharge is needed for vacuuming If leakage is found please fasten the joint more tightly 6 After closing the valve of charging hose disconnect the tank and connect the vacuum pump to charging hose and open the val...

Страница 37: ...as side slightly and then close it tightly 3 Operate the air conditioner for 10 15 min until cycle is stabilized 4 Close the spindle of service port liquid side high pressure and wait till pressure of gas side low pressure drops below 0kgf cm2 5 After the needle of gage indicates below 0 kgf cm2 close the valve of gas side quickly and turn off the power 6 Disconnect the piping between indoor and o...

Страница 38: ...roximately 150g each time while operating the air conditioner in the cooling cycle however one time is not sufficient wait approximately 1 minute and then repeat the procedure 4 Immediately disconnect the charge hose from the 3 way valve s service port Stopping partway will allow the gas to be discharged If the system has been charged with liquid refrigerant while operating the air conditioner tur...

Страница 39: ...room air humidity When the room air humidity is relativery higher temperature difference is smaller When the room air humidity is relatively lower temperature difference is larger 2 Check temperature and pressure of refrigeration cycle Notice 1 The suction pressure is usually 4 5 6 0 kg cm2 G at normal condition 2 The temperature can be measured by attaching the thermometer to the low pressure tub...

Страница 40: ...YES Is the input voltage of transformer AC230V Check the FUSE and the wiring diagram Is the PIN 49 58 of MICOM DC5V Exchange MICOM YES NO Check the main P C B pattern NO YES Is the output voltage of IC03D DC5V NO Exchange IC03D Is the input voltage of IC03D about AC12V Check the 5V P C B pattern ...

Страница 41: ...s the each Relay any problem YES NO YES It is normal operation Exchange IC01M Exchange Relay YES YES NO YES Is it Heating Mode Does the temperature set all right Change IC01M NO NO Adjust operation mode Adjust set temperature Is IC01M operated normally YES Check the connector CN OUT Check RY 4Way NO Is 4way valve operated Possible Trouble 3 Ineffective Heating ...

Страница 42: ... YES Is the LCD operated normally Is the terminal of wired Remocon T2 DC12V Is the pin 39 40 of Micom DC 5V Change the wired Remocon Check the wired Remocon PCB and DC 12V pattern NO NO Check the parts of communication Connector CN Remo and terminals of wired Remocon exactly ...

Страница 43: ... 43 Electronic control device MAIN P C B ASM ...

Страница 44: ...1HL CL LB F3063HL CL LB F3661HL CL LB F3663HL CL LB F3681HL CL LB F3683HL CL LB F4261HL CL LB F4263HL CL LB E4881HL CL LB E4883HL CL LB E6081HL CL LB E6083HL CL 330860 152302 268714 237204 1 35211C 2 35211C 1 267110 1 267110 2 249951 346810 336610 1 336610 2 359012 2 359012 1 354210 237204 2 552111 352118 W0CZZ 263230 1 263230 2 ...

Страница 45: ...3661A10009A 3661A10009A 3661A10009A 3661A10009C R 336610 2 HOUSING ASSY MECH 3661A10009B 3661A10009B 3661A10009B 3661A10009B 3661A10009D R 346810 MOTOR ASSY INDOOR 4681A20005L 4681A20005L 4681A20005L 4681A20005L 4681A20005M R 4681A20005W 4681A20005W 4681A20005W 4681A20005W 4681A20005X R 35211C 1 TUBE ASSY DISCHARGE 5211A30094A 5211A30094A 5211A30094A 5211A30094A 5211A30094A R 35211C 2 TUBE ASSY DI...

Страница 46: ...009C 3661A10009C 3661A10009C 3661A10009C R 336610 2 HOUSING ASSY MECH 3661A10009D 3661A10009D 3661A10009D 3661A10009D R 346810 MOTOR ASSY INDOOR 4681A20005M 4681A20005M 4681A20005M 4681A20005M R 4681A20005X 4681A20005X 4681A20005X 4681A20005X R 35211C 1 TUBE ASSY DISCHARGE 5211A30094A 5211A30094A 5211A30094A 5211A30094A R 35211C 2 TUBE ASSY DISCHARGE 5211A30094B 5211A30094B 5211A30094B 5211A30094B...

Страница 47: ...E 3661A10009E 3661A10009E R 336610 2 HOUSING ASSY MECH 3661A10009D 3661A10009F 3661A10009F 3661A10009F 3661A10009F R 346810 MOTOR ASSY INDOOR 4681A20005M 4681A20005K 4681A20005K 4681A20005Q 4681A20005Q R 4681A20005X 4681A20005U 4681A20005U 4681A20005V 4681A20005V R 35211C 1 TUBE ASSY DISCHARGE 5211A30077A 5211A30077A 5211A30077A 5211A30077A 5211A30077A R 35211C 2 TUBE ASSY DISCHARGE 5211A30094B 52...

Страница 48: ...L CL LB D2461HL CL LB D2463HL CL LB F3061HL LB F3063HL 437210 349480 435301 435512 546810 552201 554031 552112 263230 W0CZZ 1 W0CZZ 2 268711 W6920 649950 554160 552203 1 552203 2 435300 137213 1 437212 137213 2 559010 C S R 552202 566000 561410 552111 ...

Страница 49: ... 552201 VALVE CHECK 3A01020H 3A01020H R 552202 VALVE REVERSING 3A02027A 3A02027A 3A02027B R 552203 1 VALVE SERVICE 2A00392E 2A00392E 2A00392E 2A00392E 2A00392E R 552203 2 VALVE SERVICE 2H02479B 2H02479B 2H02479B 2H02479B 2A00393Q R 554031 CONDENSER ASSY BENT 5402AR2347B 5402AR2347H 5402AR2347B 5402AR2347H 6140AP2096Q R 554160 COMPRESSOR 5416A20016A 5416A20016A 5416A20016B 5416A20016B 2A01032A R 55...

Страница 50: ...61HL CL LB F3663HL CL LB F3681HL CL LB F3683HL CL 552203 2 552203 1 437212 137213 435512 435301 554031 2 W6920 566001 263230 W0CZZ 1 567480 554160 552202 561410 566000 W0CZZ 2 554031 1 437210 546810 559010 268711 649950 552111 552201 ...

Страница 51: ...2A 2A00392A R 552203 2 VALVE SERVICE 2A00393A 2A00393A 2A00393A 2A00393A R 554031 1 CONDENSER ASSY BENT 5403A20006A 5403A20006A 5403A20006A 5403A20006A R 554031 2 CONDENSER ASSY BENT 5403A20006G 5403A20006G 5403A20006G 5403A20006G R 554160 COMPRESSOR ASSY FINAL 5417A90001F 5417A90001F 5417A90001E 5417A90001E R 559010 FAN ASSY PROPELLER 1H00156B 1H00156B 1H00156B 1H00156B R 561410 COIL ASSY REVERSI...

Страница 52: ... LB E4881HL CL LB E4883HL CL LB E6081HL CL LB E6083HL CL 435512 546810 554031 1 649950 552203 2 437212 552203 1 559010 435301 437210 137213 567480 548490 552202 561410 263230 268711 W0CZZ 1 W0CZZ 2 566001 552115 552111 566000 554160 W6920 552201 554031 2 ...

Страница 53: ...NG 3A02080A 3A02080A 3A02080A R 552203 1 VALVE SERVICE 2A00393Q 2A00393Q 2A00393Q 2H0189G 2H0189G R 552203 2 VALVE SERVICE 2A00499A 2A00499A 2A00499A 2A00499A 2A00499A R 554031 1 CONDENSER ASSY BENT 5403AP2378K 5403AP2378D 5403A20001H 5403AP2378D 5403A20003M R 554031 2 CONDENSER ASSY BENT 5403AP2378Z 5403AP2378F 5403A20001H 5403AP2378F 5403A20003P R 554160 COMPRESSOR ASSY FINAL 5416A10001A 5417A30...

Страница 54: ...P No 3828A30023K December 2000 Printed in Korea P No 3828A20050B June 2001 Printed in Korea ...

Отзывы: