4. TROUBLE SHOOTING
- 32 -
Charging Trouble (2)
START
No
Voltage at VCHG of U200
= 5.2V?
Yes
The charging adaptor(TA) is
out of order.
Change the charging adaptor
No
Resolder
U200, R221,R219
Yes
Voltage at R207 is
0V?
No
Yes
Battery is OK?
No
The battery may
have problems.
Change the battery.
Charging is
operating properly.
Yes
Change
U200
U200, R221, R219
Well-Soldered?
Содержание KG330
Страница 3: ... 4 ...
Страница 10: ...3 Technical Brief 11 BaseBand Components Speaker Vibrator Speaker ...
Страница 12: ...3 Technical Brief 13 BaseBand Components Touch FPCB U100 CN100 U100 Touch Sensor CN100 B to B conn ...
Страница 13: ...3 Technical Brief 14 3 2 Digital Baseband DBB Processor Block diagram of the D751685 Calyso Plus ...
Страница 14: ...3 Technical Brief 15 3 3 Analog Main Processor ABB Block diagram of the TWL3016 ...
Страница 38: ...4 TROUBLE SHOOTING 39 Speaker Trouble 2 Test Point U209 Speaker Soldering Check C536 C535 ...
Страница 75: ...4 TROUBLE SHOOTING 76 2 Checking VCTCXO Circuit ...
Страница 77: ...4 TROUBLE SHOOTING 78 3 Checking RF Chipset Control Signal ...
Страница 85: ...4 TROUBLE SHOOTING 86 2 Checking VCTCXO Circuit ...
Страница 87: ...4 TROUBLE SHOOTING 88 3 Checking RF Chipset Control Signal ...
Страница 98: ...5 Downloading Software 99 The Procedure of Downloading Software 4 4 Press Start Button MG210 ...
Страница 100: ...5 Downloading Software 101 The Procedure of Downloading Software 6 6 SW downloading Condition MG210 ...
Страница 101: ...5 Downloading Software 102 The Procedure of Downloading Software 7 7 SW downloading END Condition MG210 ...
Страница 103: ... 104 ...
Страница 115: ... 116 8 PCB Layout Main PCB layout TOP ...
Страница 116: ... 117 8 PCB Layout Main PCB layout Bottom ...
Страница 117: ... 118 8 PCB Layout Camera Sub PCB ...
Страница 118: ... 119 8 PCB Layout Camera Sub PCB ...
Страница 119: ... 120 ...
Страница 122: ...9 Calibration 123 4 Click on CALIBRATION START button KG330 338 KG330 338 ...
Страница 124: ...9 Calibration 125 2 Standalone Test Setup Oscilloscope ...
Страница 126: ...9 Calibration 127 3 TX Standalone Test Setup ...
Страница 128: ...9 Calibration 129 4 RX Standalone Test Setup ...
Страница 129: ... 130 ...
Страница 131: ... 132 ...
Страница 154: ...Note ...
Страница 155: ...Note ...