Instructions for the Installer
For operation on 380-415 V 3N~:
use an H05V2V2-F - type five-
core cable (5 x 1.5 mm
2
) heat-resistant to at least 90°C.
For operation on 380-415V 2N~:
use an H05V2V2-F - type four-
core heat-resistant to at least 90°C. cable (4 x 2.5 mm
2
)
For operation on 220-240 V 3~:
use an H05V2V2-F - type four-
core heat-resistant to at least 90°C. cable (4 x 2.5 mm
2
)
For operation on 220-240V~:
30 cm hobs: use an H05V2V2-F type three-core cable,
heat-resistant to at least 90°C.
(cable 3 x 1.5 mm
2
)
60-70 cm hobs:
use an H05V2V2-F type three-core cable,
heat-resistant to at least 90°C.
(cable 3 x 4 mm
2
)
90 cm hobs
use an H05V2V2-F type three-core cable,
heat-resistant to at least 90°C.
(cable 3 x 6 mm
2
)
The earth wire (yellow-green) must be at least 20 mm longer than the
other wires at the end for connection to the appliance.
Depending on the hob you have purchased, the possible electrical
connections are: 30 cm hobs:
220-240V~
60-70 cm hobs:
220-240V~/ 220-240V 3~/ 380-415V 2N~
90 cm hobs:
220-240V~/ 220-240V 3~/ 380-415V 2N~/ 380-415V 3N~
Read the connection layout plate underneath the appliance or
around the power cable withH care.
The manufacturer declines all responsibility
for damage to
persons or things caused by non-observance of the above
prescriptions or by interference with any part of the appliance.