SETTING : “Vibrator on” at Sounds of test menu
Checking Flow
START
Vibrator will
Work properly
No
No
No
Yes
Yes
Yes
No
Yes
Check the state of
Contact of Vibrator
Re-contact vibrator
Is the voltage across LED414
over 2.5V?
Is the voltage across R436
Under 3V?
Check the signal level at
MSM_MOTOR_EN=high?
Replace MSM
Replace Vibrator
Does Vibrator work Properly?
Yes
No
Check the soldering of
Q406, R417, LED400
Re-soldering
Q406, R417, LED414
No
Replace
Q406, R417, LED414
Yes
Re-soldering
Q403, R436
Check the soldering of
Q403, R436
No
Replace
Q403, R436
Yes