LG ICR18650B3 Скачать руководство пользователя страница 5

 

PRODUCT SPECIFICATION 
CONFIDENTIAL 

 

Description 

Date 

Rev 

Lithium Ion ICR18650 B3 2600mAh 

2007-09-14 

 

 5/8

 

 

 

 

4.3 Environmental specification. 

Item 

Condition 

Specification 

4.3.1  

Storage Characteristics 

Cells shall be charged per 4.1.1 and stored in a 

temperature-controlled environment at 23ºC ± 

2ºC for 30 days. After storage, cells shall be 

discharged per 4.1.2 to obtain the remaining 

capacity. 

Capacity remaining rate 

  90% (C

min

 in 2.1) 

4.3.2  

High Temperature 

Storage Test 

Cells shall be charged per 4.1.1 and stored in a 

temperature-controlled environment at 60ºC for 

1 week. After storage, cells shall be discharged 

per 4.1.2 and cycled per 4.1.3 for 3 cycles to 

obtain recovered capacity

No leakage,   

Capacity recovery rate 

 

80% 

4.3.3  

High Temperature and 

High Humidity Test 

Cells are charged per 4.1.1 and stored at 60ºC 

(95% RH) for 168 hours. After test, cells are 

discharged per 4.1.2 and cycled per 4.1.3 for 3 

cycles to obtain recovered capacity. 

No leakage, No rust 

Capacity recovery rate 

 

80% 

4.3.4  

Thermal Shock Test 

65ºC (8h) 

 3hrs 

 -20ºC (8h) for 8 cycles 

with cells charged per 4.1.1 After test, cells are 

discharged per 4.1.2 and cycled per 4.1.3 for 3 

cycles to obtain recovered capacity. 

No leakage   

Capacity recovery

 

rate 

 

80% 

Cells shall be charged per 4.1.1 at 23ºC ± 2ºC 

and discharged per 4.1.2 at the following 

temperatures.  

 

4.3.5  

Temperature 

Dependency of 

Capacity 

Charge Discharge Capacity 

 

-10

 

60% of C

ini

 

 

0

 

90% of C

ini

 

 

23

 

100% of C

ini

 

 

23

 

60

 

95% of C

ini

 

 

 

4.4 Mechanical Specification 

                                                      

* Remaining Capacity : After storage, cells shall be discharged with Std. condition(4.1.2) to measure the remaining capacity. 
** Recovery Capacity : After storage, cells shall be discharged with fast discharge condition(4.1.3), and then cells shall be charged with std. 
charge condition(4.1.1), and then discharged with Std. condition(4.1.2). This charge / discharge cycle shall be repeated three times to measure 
the recovery capacity.

 

Содержание ICR18650B3

Страница 1: ...LRB PS CY260 2007 9 14 1 Approved Description LGC MEC BTC Kim Soo Ryoung Lithium Ion ICR18650 B3 2600mAh PRODUCT SPECIFICATION Rechargeable Lithium Ion Battery Model ICR18650 B3 2600mAh 20 YOIDO DONG YOUNGDUNGPO GU SEOUL 150 721 KOREA TEL 82 2 3773 1114 FAX 82 2 3773 7005 http www lgchem com ...

Страница 2: ... Nominal Voltage 2 3 Standard Charge 2 4 Max Charge Current 2 5 Standard Discharge 2 6 Max Discharge Current 2 7 Weight 2 8 Operating Temperature 2 9 Storage Temperature for shipping state 3 Appearance and Dimension 5 3 1 Appearance 3 2 Dimension 4 Performance Specification 6 4 1 Standard Test Condition 4 2 Electrical Specification 4 3 Environmental Specification 4 4 Mechanical Specification 4 5 S...

Страница 3: ...n Note Specification Nominal 2 600mAh Cnom 2 1 Capacity Std charge discharge Minimum 2 500mAh Cmin 2 2 Nominal Voltage Average 3 65 V Constant current 0 5C 1250mA Constant voltage 4 2V 2 3 Standard Charge Refer to 4 1 1 End current Cut off 50mA 2 4 Max Charge Current 1 0C 2500mA Constant current 0 2C 500mA 2 5 Standard Discharge Refer to 4 1 2 End voltage Cut off 3 0V 2 6 Max Discharge Current For...

Страница 4: ... Standard Discharge Standard Discharge shall consist of discharging at a constant current of 0 2C to 3 0V Discharging is to be performed at 23 ºC 2 ºC unless otherwise noted such as capacity versus temperature 4 1 3 Fast Charge discharge condition Cells shall be charged at constant current of 0 5C to 4 2V with end current of 50mA Cells shall be discharged at constant current of 0 5C to 3 0V Cells ...

Страница 5: ...st cells are discharged per 4 1 2 and cycled per 4 1 3 for 3 cycles to obtain recovered capacity No leakage No rust Capacity recovery rate 80 4 3 4 Thermal Shock Test 65ºC 8h 3hrs 20ºC 8h for 8 cycles with cells charged per 4 1 1 After test cells are discharged per 4 1 2 and cycled per 4 1 3 for 3 cycles to obtain recovered capacity No leakage Capacity recovery rate 80 Cells shall be charged per 4...

Страница 6: ...he charge current Charging is continued for 7 hours Per UL1642 No explode No fire 4 5 2 External Short Circuiting Test Cells are charged per 4 1 1 and the positive and negative terminal is connected by a 100mΩ wire for 1 hour Per UL1642 No explode No fire 4 5 3 Overdischarge Test Cells are discharged at constant current of 0 2C to 250 of the minimum capacity No explode No fire 4 5 4 Heating Test C...

Страница 7: ...y in direct sunlight or heat y Do not use the battery in high static energy environment where the protection device can be damaged y When rust or smell is detected on first use please return the product to the seller immediately y The battery must be away from children or pets y When cell life span shortens after long usage please exchange to new cells Prohibitions y Do not use different charger D...

Страница 8: ...PRODUCT SPECIFICATION CONFIDENTIAL Description Date Rev Lithium Ion ICR18650 B3 2600mAh 2007 09 14 1 8 8 Appendix Cell Image ...