background image

ENGLISH

Maintenance and Service

Indoor Unit

Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and 

unplug the power cord.

Clean the unit with a soft dry cloth. Do not use bleach or abrasives.

Never use any of these 

• Water hotter than 40°C. It may cause deformation and discoloration.

• Volatile substances. They may damage the surface of the air conditioner.

Air Filters

The air filters behind the front panel / grill should be checked and

cleaned once in every 2 weeks or more often if necessary. To

remove the filters see the self explanatory diagrams for each

model type. Clean the filters with a vacuum cleaner or warm

soapy water. If dirt is not easily removed, wash with a solution of

detergent in luke warm water. Dry well in shade after washing and

reinstall the filters back in place.

Plasma Filters

The plasma filters behind the air filter should be checked and

cleaned once in every 3 months or more often if necessary. To

remove the filters see the self explanatory diagrams for each

model type. Clean the filters with a vacuum cleaner. If it is dirty

wash it with water and dry well in shade an install back in place.

Virus & Allergy safe Filters, Triple Filter

Remove the Virus & Allergy safe Filter and Triple Filters behind 

the air filter and expose expose them in direct sunlight for 2 hours. 

And then insert these filters into original position.

Maintenance and Service

Gasoline

Powder

Room Air Conditioner 

16

Removal of Filters

Open the front panel as shown.

Then pull the filter tab slightly forward to remove the air filter.

After removing the air filter remove the plasma and Virus & Allergy safe Filter by slightly pulling downwards.

Plasma filter

Don't touch this plasma filter within 10 seconds after opening the inlet grille, it may cause an electric shock.

Содержание Hercules 2.0 S05LPBX-2

Страница 1: ...R Please read this manual carefully before operating your set and retain it for future reference P NO MFL67104806 www lge com TYPE WALL MOUNTED MODELS 2 0 S05LPBX 2 S09LPBX 2 S07LPBX 2 S12LVX 2 S12LPBX 2 S05LVX 2 S09LVX 2 S07LVX 2 ...

Страница 2: ...ay with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temporary Use of an Adapter 6 Temporary Use of an Extension Cord 6 Symbols used in this Manual 6 C Product Introduction 7 Indoor Units 7 Operation Indication Lamps 7 Outdoor Unit 7 D Oper...

Страница 3: ...overofcontrol boxsecurely There is risk of fire or electric shock due to dust water etc Usethecorrectlyratedbreakerorfuse There is risk of fire or electric shock Donotmodifyorextendthepowercable Ifthepowercableorcordhasscrathesor skinpeeledoffordeterioratedthenit mustbereplaced There is risk of fire or electric shock Forinstallation removalorreinstall alwayscontactthedealeroran AuthorizedServiceCe...

Страница 4: ... failure If strange sounds smell or smoke comes from product Immediately turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire Ventilate the product room from time to time when operating it together with a stove or heating element etc Oxygen deficiency can occur and hence harm your health Turn the main power off and unplug the unit when cleaning or repai...

Страница 5: ...cifiedrefrigerantusedinthesystem Ifairenterstherefrigerantsystem an excessivelyhighpressureresults causing equipmentdamageorinjury Iftherefrigerantgasleaksduringthe installation ventilatetheareaimmediately Otherwiseitcanbeharmfullforyourhealth Dismantlingtheunit treatmentofthe refrigerantoilandeventualpartsshould bedoneinaccordancewithlocaland nationalstandards Replacetheallbatteriesintheremote co...

Страница 6: ...nuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the applia...

Страница 7: ... Lamps Operation lamp Signal Receiver ON OFF button Air inlet Plasma filter Optional Air filter Front grille Vertical louver Allergy free filter Optional Air outlet Horizontal vane Horizontal vane Power Power lamp lights up during Cooling Operation Timer Timer lamp lights up during Timer Operation Outdoor Outdoor lamp lights up during Purifier Operatio n During Air Circulation Operation Power lamp...

Страница 8: ...NOTE 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth to clean them 3 In case some other appliances also get operated with remo...

Страница 9: ...desired horizontal airflow direction 13 VERTICAL AIRFLOW DIRECTION CONTROL OPTIONAL Used to set the desired vertical airflow direction 15 AUTO CLEAN BUTTON OPTIONAL Used to set auto clean mode 16 ENERGY SAVING COOLING MODE BUTTON OPTIONAL 9 Owner s Manual Used to set energy saving cooling mode operation In some models this button has a 2nd function of LED luminosity control 3 ROOM TEMPERATURE SETT...

Страница 10: ...elector and set to CHAOS mode In this mode the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C and for heating the temperature range is 16 C 30 C 3 Operation Mode MODE Cooling H...

Страница 11: ... with respect to the setting temperature Operating Instructions Artificial intelligence function judges and operates the set temperature and fan level based room temperature to provide pleasant environment to the user Artificial intelligence can be categorized largely into cool and dehumidifier artificial intelligence If the user selects artificial intelligence function during cool operation it op...

Страница 12: ...lable only in some models warms up the room quickly by operating at super high fan speed and 30 C setting temperature for 60 minutes Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons This plasma kills and destroys the contaminants completely to provide clean and hygienic air You can activate this o...

Страница 13: ...s remote controller sets If you want to use this operation Press and hold the ON OFF button for 3 5 seconds then the buzzer sound 1 beep If you want to stop the operation re press the button 13 Owner s Manual ON OFF button Energy saving cooling mode can save energy in cooling because it body adaptation time according to the change of time and temperature and adjusting automatically desired 1 Press...

Страница 14: ...ON OFF TIMER BUTTONS to turn timer on or off 3 Press the TIME SETTING BUTTONS until the desired time is set 4 To set the selected time press the SET CLEAR BUTTON aiming the remote controller at the signal receptor To cancel the timer setting Press the SET CLEAR BUTTON aiming the remote controller at the signal receptor The timer lamp on the air conditioner and the display will go off Select one of...

Страница 15: ...N to start the unit 2 Press the vertical airflow direction button Each time the button is pressed the air flow direction is changed in the direction of the arrow STOP 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step Auto Swing Horizontal Vane Control Optional Vertical Vane Control Optional Press the Vertical Airflow Direction button once more during Auto Swing at the direction of airflow you want The Ver...

Страница 16: ...ll the filters back in place Plasma Filters The plasma filters behind the air filter should be checked and cleaned once in every 3 months or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner If it is dirty wash it with water and dry well in shade an install back in place Virus Allergy safe Filters Triple Filt...

Страница 17: ...uch a situation Do not overcool the room This is not good for the health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Make sure that the doors and windows are shut thight Avoid ...

Страница 18: ...ip Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Clean the filter at least every 2 weeks See the Maintenance and Service section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns Make sure they are correct Check and remove such source or turn it off...

Страница 19: ...PT LG ELECTRONICS INDONESIA Kawasan Industri MM2100 Blok G Cikarang Barat Bekasi Jawa Barat 17520 INDONESIA ...

Страница 20: ...TIPE PEMASANGAN DI DINDING Harap membaca buku petunjuk ini dengan seksama sebelum mengoperasikan unit AC Anda dan simpanlah sebagai referensi jika suatu saat diperlukan MODELS 2 0 S05LPBX 2 S09LPBX 2 S07LPBX 2 S12LVX 2 S12LPBX 2 S05LVX 2 S09LVX 2 S07LVX 2 ...

Страница 21: ...mecahan Masalah Hemat waktu dan biaya 18 Segera hubungi teknisi servis pada situasi berikut 18 UNTUK CATATAN ANDA BACALAH BUKU PETUNJUK INI Di dalam buku ini terdapat banyak petunjuk berguna mengenai cara menggunakan dan merawat AC Anda dengan tepat Perhatian atas tindakan pencegahan yang sederhana pada komponen AC Anda dapat menghemat banyak waktu dan biaya selama masa penggunaan AC Anda Anda dap...

Страница 22: ... kejutan listrik Terdapat risiko kebakaran atau kejutan listrik karena debu air dll Gunakanlah pemutus sirkuit atau sekring yang tepat Jangan memodifikasi atau memanjangkan kabel daya Jika kabel atau kawat daya tergores atau kulitnya terkelupas atau menurun kualitasnya maka perlu diganti Untuk pemasangan pelepasan atau pemasangan kembali hubungilah selalu dealer atau Pusat Servis Resmi Terdapat ri...

Страница 23: ... buruk pada kesehatan Anda Terdapat risiko cedera fisik kejutan listrik atau kegagalan fungsi unit Terdapat risiko kejutan listrik atau kebakaran Sesekali bukalah ventilasi ruangan apabila mengoperasikan unit AC bersamaan dengan kompor atau elemen pemanas dll Matikan daya utama dan cabut steker ketika membersihkan atau memperbaiki unit AC Apabila unit AC akan tidak digunakan dalam waktu yang lama ...

Страница 24: ...sangan segera buka ventilasi ruangan Air pengembunan yang terdapat di dalam unit dapat tumpah Jika udara masuk ke dalam sistem pendingin hal itu dapat mengakibatkan tekanan tinggi yang berlebihan sehingga menyebabkan kerusakan peralatan atau cedera Dapat berbahaya bagi kesehatan Anda Pembongkaran unit penanganan oli pendingin dan komponen bekas harus dilakukan sesuai dengan standar lokal dan nasio...

Страница 25: ...ya bahaya keselamatan Untuk hubungan sementara gunakanlah hanya adaptor yang asli yang disediakan di hampir seluruh toko perkakas terdekat Pastikan slot besar pada adaptor cocok dengan slot besar pada stop kontak untuk hubungan polaritas yang tepat Untuk melepaskan kabel daya dari adaptor gunakan masing masing satu tangan untuk menghindari kerusakan pada terminal ground Hindari seringnya mencabut ...

Страница 26: ...irkulasi Udara lampu Power Daya menyala Ketika Outdoor beroperasi dengan Pengoperasian Surkulasi Udara lampu Power Daya dan lampu Outdoor menyala bersamaan Lampu Indikasi Pengoperasian Unit Dalam Ruangan Lampu pengoperasian Penerima Sinyal Tombol ON OFF Nyala Mati Masukan Udara Filter plasma Opsional Filter udara Filter udara Gril depan Berikut adalah pengenalan singkat tentang unit dalam dan luar...

Страница 27: ...TATAN 1 Penerima sinyal berada di dalam unit AC 2 Arahkan remote control pada unit untuk mengoperasikannya Tidak boleh ada penghalang di antara remote control dan unit AC 1 Pilihlah lokasi yang tepat yang aman dan mudah dicapai 2 Pasang penahan dengan kuat pada dinding dll dengan sekrup yang tersedia 3 Masukkan remote control ke dalam penahan 1 Remote control tidak boleh terkena sinar matahari lan...

Страница 28: ... mengaktifkan atau menonaktifkan pendinginan cepat Mengoperasikan kipas pada kecepatan supertinggi dalam mode pendinginan 7 TOMBOL TIMER ON Digunakan untuk mengatur waktu mulainya pengoperasian 8 TOMBOL TIMER OFF Digunakan untuk mengatur waktu penghentian pengoperasian 9 TOMBOL PENGATURAN WAKTU Digunakan untuk menyetel waktu 10 TOMBOL SET CLEAR TIMER Digunakan untuk menetapkan dan menghapus pengop...

Страница 29: ... kecepatan kipas sesuai dengan logika CHAOS Petunjuk Pengoperasian 1 Tekan TOMBOL START STOP untuk menyalakan unit Unit akan memberikan respon dengan suara bip 2 Buka tutup remote control dan tekan tombol mode pengoperasian Setiap kali tombol ditekan mode pengoperasian akan berubah sesuai arah tanda panah 3 Untuk operasi pendinginan atau pemanasan tetapkan temperatur dalam ruangan yang diinginkan ...

Страница 30: ...ruangan 26ºC 25ºC Pengoperasian Anti lembab yang Sehat Pengoperasian otomatis pada dasarnya adalah fungsi pemanasan atau pendinginan yang dilakukan oleh unit AC Namun selama pengoperasian ini remote control mengubah mode pengoperasian secara otomatis untuk mempertahankan temperatur dalam 2 C terhadap temperatur latar Selama Pengoperasian Anti lembab yang Sehat Jika Anda memilih mode anti lembab de...

Страница 31: ...n temperatur latar 18 C selama 30 menit untuk pendinginan yang cepat dan efektif Demikian pula fungsi jet heat hanya tersedia pada beberapa model akan memanaskan ruangan dengan cepat dengan kecepatan kipas supertinggi dan temperatur latar 30 C selama 60 menit Pembersihan Otomatis Opsional Pengoperasian Pemurnian Udara NEO PLASMA Opsional Filter plasma adalah teknologi yang dikembangkan oleh LG unt...

Страница 32: ...n secara otomatis Pengoperasian akan dimulai ketika tombol ON OFF ditekan Jika Anda ingin menghentikan pengoperasian tekan tombol sekali lagi Model Pendinginan Model pompa Panas Temperatur Ruangan 24 C 21 C Temperatur Ruangan 24 C Temperatur Ruangan 21 C Mode pengoperasian Pendinginan Pendinginan Anti lembab yang sehat Pemanasan Kecepatan KIPAS Dalam Ruangan Tinggi Tinggi Tinggi Tinggi Temperatur ...

Страница 33: ...ekan TOMBOL SET CLEAR dengan mengarahkan remote control pada penerima sinyal Lampu timer pada unit AC dan tampilan akan mati Pilih satu dari empat tipe pengoperasian berikut Tekan TIMER ON atau TIMER OFF untuk memeriksa penetapan waktu ModeTidur MengaturWaktu Saat Ini PengaturanTimer Timer tertunda on Timer tertunda on dan off SET CLEAR SET CLEAR SET CLEAR SET CLEAR OFF TIMER ON OFF TIMER ON SET C...

Страница 34: ... yang Anda inginkan 1 Tahap 2 Tahap 3 Tahap 4 Tahap 5 Tahap Auto Swing Kiri Auto Swing Kanan Auto Swing Penuh Pengoperasian ini mensirkulasikan udara tanpa pendinginan atau pemanasan Mode ini dapat diaktifkan dengan menekan TOMBOL PILIHAN MODE PENGOPERASIAN Setelah sirkulasi udara diaktifkan Anda dapat memilih kecepatan aliran udara dengan menekan TOMBOL PILIHAN KECEPATAN KIPAS DALAM RUANGAN Udara...

Страница 35: ...Filter Udara Filter udara di belakang panel gril depan harus diperiksa dan dibersihkan satu kali setiap 2 minggu atau lebih sering jika diperlukan Untuk melepaskan filter lihat diagram penjelasan untuk setiap tipe model Bersihkan filter dengan menggunakan pembersih vakum atau air sabun hangat Jika kotoran tidak mudah dihilangkan cucilah dengan larutan deterjen dalam air hangat hangat kuku Jemur sa...

Страница 36: ...esehatan dan boros listrik Jangan biarkan sinar matahari langsung masuk ke dalam ruangan ketika AC beroperasi Lakukan penyetelan arah aliran udara vertikal dan horisontal untuk memastikan temperatur yang seragam di dalam ruangan Pastikan pintu dan jendela tertutup rapat Bersihkan filter udara secara teratur Sesekali biarkan ruangan mendapatkan ventilasi udara Gunakan kecepatan kipas yang tinggi un...

Страница 37: ...n steker AC telah ditancapkan sepenuhnya pada stop kontak Sekring putus pemutus sirkuit jatuh Periksa kotak pemutus sirkuit sekring rumah dan ganti sekring atau reset pemutus sirkuit Kegagalan daya Jika terjadi kegagalan daya matikan kontrol mode Ketika daya telah tersedia tunggu hingga 3 menit untuk merestart unit AC guna mencegah jatuhnya pemutus sirkuit akibat kelebihan beban kompresor Tegangan...

Страница 38: ...PT LG ELECTRONICS INDONESIA Kawasan Industri MM2100 Blok G Cikarang Barat Bekasi Jawa Barat 17520 INDONESIA ...