80
No.
Error Code
Contents of fail
Fail Analysis
Block Diagram
SSB Byte8,9
1
28xx
LP Adjust NG.
1) Check Pickup FFC Connection.
No.01
2) Check solder of IC101circumference.
(pin#10, 14, 16, L101, L103)
3) Check solder of IC105.
4) Exchange Pickup(LDD, Front Monitor).
5) Exchange IC101(AFE).
6) Exchange IC801(MPU).
7) Exchange IC701(DSP).
2
48xx
High Frequency Adjust NG.
1) Check Pickup FFC Connection.
No.02
2) Exchange Pickup (LDD part).
3) Exchange IC701(DSP).
3
4C0x to 4C4x
Data Slice Adjust NG.
1) Check solder of IC101circumference.
No.03
(pin# 77, IC107, IC108, L101, L103)
2) Exchange IC101(AFE).
3) Exchange IC701(DSP).
4
4C5x to 4C7x
EQ Boost Adjust NG.
1) Check solder of IC101circumference.
(pin# 77, IC107, IC108, L101, L103)
2) Exchange IC101(AFE).
3) Exchange IC701(DSP).
5
4C80
RAW Slice Level Adjust NG.
1) Check solder of IC101circumference.
(pin# 77, IC107, IC108, L101, L103)
2) Exchange IC101(AFE).
3) Exchange IC701(DSP).
6
4CAx
EQ Auto Frequency Adjust NG. 1) Check solder of IC101circumference.
(pin# 77, 65, IC107, IC108, L101, L103)
2) Exchange IC101(AFE).
3) Exchange IC701(DSP).
Detail Error Code & Fail Analysis
1. Laser Power Initial Adjust
(Exchange
low/high byte)
Byte8: xxh
Byte9: 28h