2. Control Method
2-1. Start Position
1. After POWER OFF or Power Outage, check the EJECTOR's position with MICOM initialization to restart.
2. How to check if it is in place:
- Check
HIGH/LOW
signals from HALL SENSOR in MICOM PIN.
3. Control Method to check if it is in place:
(1) EJECTOR is in place,
- It is an initialized control, so the mode can be changed to ice making control.
(2) EJECTOR isn't in place:
A. If EJECTOR is back in place within 2 minutes with the motor on, it is being initialized. If not, go to Step B.
B. If EJECTOR is back in place within 18 minutes with the heater on (to control Heater on its OFF condition), it is being
initialized. If not, it is not functioning. Repeat Step B with Heater and Motor off.
2-2. Icemaking Mode
1. Icemaking control refers to the freezing of supplied water in the ice trays. Complete Icemaking operations by measuring
the temperature of the Tray with Icemaking SENSOR.
2. Icemaking starts after completing fulfilled ice control and initial control.
3. The Icemaking function is completed when the sensor reaches 19°F(-7°C), 60 to 240 minutes after starting.
4. If the temperature sensor is defective, the Icemaking function will be completed in 4 hours.
2-3. Harvest with Dump Mode
1. Harvest with Dump control refers to the operation of dropping cubes into the ice bin from the tray when Icemaking has
completed.
2. Harvest with Dump control mode:
(1) Operates Heater for 30 seconds; then operate MOTOR.
(2) After performing Step 1 (to control the Heater on its off condition), Ice-Removal control will be back in place wthin 18
minutes. (Hall SENSOR sign = OV). Ice removal is then complete. Then change the mode to the water supply control.
If this control phase fails to start, it is not functioning. Put the Heater and Motor in the off position. Restart every 2
hours. (Refer to fig.1)
NOTE :
If the motor malfunctions and starts before the detect lever rises, MICOM regards the Ice-Removing phase as
completed. Water then starts flowing. To prevent this, MICOM doesn’t switch to water-supply mode, but restarts the ice-
removing mode. If this happens 3 times, the motor is malfunctioning and you should stop the loads (Heater, Motor). Then
restart the Ice-Removing mode every 2 hours. (See Step 2 above.)
OPERATION PRINCIPLE AND REPAIR METHOD OF ICEMAKER
- 66 -
Heater
on
off
on
0V
5V
off
30 sec.
10 sec.
Motor
Hall IC
Ice removing
completion point
2 ms
Icemaking sensor temperature is 50
°
F(10˚C)
or more
Max. 18 minutes
After detect LEVER rises
Содержание GR-B277
Страница 41: ...2 GR B277 EXPLANATION FOR MICOM CIRCUIT 41 a b c d ...
Страница 50: ...2 GR B277 EXPLANATION FOR MICOM CIRCUIT 50 ...
Страница 51: ...2 2 Parts list 1 GR L267 G267 P277 EXPLANATION FOR MICOM CIRCUIT 51 ...
Страница 52: ...EXPLANATION FOR MICOM CIRCUIT 52 ...
Страница 53: ...2 GR B277 EXPLANATION FOR MICOM CIRCUIT 53 ...
Страница 54: ...EXPLANATION FOR MICOM CIRCUIT 54 ...
Страница 55: ...2 3 DISPLAY ASSEMBLY part diagram 1 GR L267 G267 P277 LCD Display EXPLANATION FOR MICOM CIRCUIT 55 ...
Страница 56: ...2 GR L267 G267 P277 LED Display EXPLANATION FOR MICOM CIRCUIT 56 ...
Страница 57: ...3 GR B277 EXPLANATION FOR MICOM CIRCUIT 57 ...
Страница 58: ...2 4 DISPLAY circuit diagram 1 GR L267 G267 P277 LCD Display EXPLANATION FOR MICOM CIRCUIT 58 ...
Страница 59: ...2 GR L267 G267 P277 LED Display EXPLANATION FOR MICOM CIRCUIT 59 PWB ASSEMBLY DISPLAY ...
Страница 60: ...3 GR B277 EXPLANATION FOR MICOM CIRCUIT 60 ...
Страница 63: ...2 GR B277 EXPLANATION FOR MICOM CIRCUIT 63 ...
Страница 64: ...EXPLANATION FOR MICOM CIRCUIT 64 ...
Страница 69: ...CIRCUIT 69 3854JD1110A ...
Страница 70: ...CIRCUIT 70 3854JD1110A ...
Страница 71: ...CIRCUIT 71 3854JD1110A ...
Страница 119: ...6 BLOCK DIAGRAM TV RADIO 119 ...
Страница 134: ...P No 3828JD8793E FEB 2005 Printed in Korea ...