1-11
Sensor resistance characteristics table
u
Resistance value allowance of sensor is ±5%.
u
When measuring the resistance value of the sensor, allow the temperature of that sensor to stabilize for at least 3 minutes
before measuring. This delay is necessary because of the sense speed relationship.
u
Use a digital tester to measure the resistance. An analog tester has to great a margin of error.
u
Resistance of the cold storage sensor 1 and 2 shall be measured with a digital tester after separating CON8 of the PWB
ASSEMBLY and the MAIN part.
u
Resistance of the freezing sensor shall be measured with a digital tester after separating CON7 of the PWB ASSEMBLY
and the MAIN part.
EXPLATION FOR MICOM CIRCUIT
-
22
-
Measuring Temperature ( °
C)
Freezing Sensor
Refrigerator sensor 1&2
Defrost sensor, Ambient sensor
-20 °
C
22.3 k
Ω
77 k
Ω
-15 °
C
16.9 k
Ω
60 k
Ω
-15 °
C
13.0 k
Ω
47.3 k
Ω
-5 °
C
10.1 k
Ω
38.4 k
Ω
0 °
C
7.8 k
Ω
30 k
Ω
+5 °
C
6.2 k
Ω
24.1 k
Ω
+10 °
C
4.9 k
Ω
19.5 k
Ω
+15 °
C
3.9 k
Ω
15.9 k
Ω
+20 °
C
3.1 k
Ω
13 k
Ω
+25 °
C
2.5 k
Ω
11 k
Ω
+30 °
C
2.0 k
Ω
8.9 k
Ω
+40 °
C
1.4 k
Ω
6.2 k
Ω
+50 °
C
0.8 k
Ω
4.3 k
Ω
Содержание GR-B207WVQ.CSWQAGE
Страница 5: ...PARTS IDENTIFICATION 5 Frame Display Cover PWB 2 Ref No Conversion switch Meats Vegetables ...
Страница 22: ...23 2 PWB Parts Drawings and List 2 1 PWB Assembly Main Parts Drawings EXPLATION FOR MICOM CIRCUIT ...
Страница 25: ...CIRCUIT The circuit has been only applied to voltage except 220v 52 ...
Страница 72: ......