7-1-10 ERROR DIAGNOSTIC MODE
1. The error diagnostic mode allows the SVC when a fault that may affect the performance of the product occurs while
operating the product.
2. Even if the function control button is pushed when an error occurs, the function will not be performed. However, the
recognition tone (beep~) sounds.
3. When the error is cleared while the error code is displayed due to a fault, the appliance returns to the normal condition
(Reset).
4. The error code is displayed by the refrigerator temp indication LED on the display of the refrigerator while the remaining
LEDs are off.
- 21 -
Error Code
Display
NO
Error
Error Code
Cause
State of Operation with Error
Display
Comp
Cooling fan
Defrosting heater
1
2
3
4
Faulty refrigerator
(R) sensor
Faulty defrosting
sensor
Faulty Room
temperature sensor
(in the main PCB)
Defrosting failure
r
d
when checking
LED, the error
code display all off.
H
Cut or short-circuited wire of
refrigerator sensor
Cut or short-circuited wire of
defrosting sensor
Cut or short-circuited wire of
intake air temperature sensor
Cut or disconnected wire of
defrosting heater or temperature
fuse(indicated at least 4 hours
later after the error occurs)
15 min ON/
15 min OFF
standard
RPM
standard
RPM
standard
RPM
standard
RPM
No defrosting
Содержание GR-642APA
Страница 34: ...7 5 MAIN PWB ASS Y AND PARTS LIST 7 5 1 MAIN PWB ASS Y 34 ...
Страница 35: ...7 5 2 REPLACEMENT PARTS LIST 35 ...
Страница 36: ...7 5 3 PWB ASS Y DISPLAY AND PARTS LIST 36 ...
Страница 37: ...7 6 PWB DIAGRAM 37 ...
Страница 38: ... 38 ...
Страница 43: ... 43 611P 611M 611Q 611A 611B 611C 611D 611H 611S 611T 611N 611R 611Y 611Z 611E 611K 611W 611X EV ...
Страница 44: ...P No 3828JD8734B OCT 2004 Printed in Korea ...