4) LOAD/BUZZER OPERATION, DOOR OPENING SENSING CIRCUIT
(1) LOAD OPERATION CHECK
ƒU
If the DOOR-R is opened during FAN MOTOR is operated, FAN MOTOR is stopped immediately.
ƒU
The A , B of DOOR S/W-R is connected DOOR OPEN DETECTION CIRCUIT as follow.
ƒU
If the DOOR-R is opened or closed, then the DOOR S/W-R is ON/OFF, and the LAMP-R is ON/OFF,
and at the same time, S/W of the A , B of DOOR S/W-R for detection of DOOR-R open is ON/OFF.
(2) DOOR OPENING PERCEPTION CHECK
*NOTICE: If you change DOOR S/W-R, you must use a component of the right PART NUMBER. There is a similar type
DOOR S/W-R of NOT MICOM MODEL, and its logic of the A , B of DOOR S/W-R is reversed.
ƒU
Even though LAMP-R is operated a normal ON/OFF according to DOOR S/W-R, the MICOM can't detect a
DOOR-R opened or closed of lead wire of the A , B is abnormal or S/W of the A , B of DOOR S/W-R is abnormal.
ƒU
When DOOR-R open isn't detected : Even though DOOR-R is opened, FAN MOTOR couldn't stop.
When DOOR-R close isn't detected : Even though DOOR-R is closed, BUZZER sounds a DOOR OPEN ALARM.
check a lead wire of the A , B and DOOR S/W-R.
- 22 -
KIND OF LOAD
COMPRESSOR,
FAN MOTOR
DEFROSTING HEATER
COMPRESSOR COOLING FAN
MEASURING POINT (IC5)
No.13
No.14
No.15
ON
below 1V
STATE
OFF
12V
MEASURING POINT
NO.6 OF IC 1 (MICOM)
REFRIGERATOR DOOR
CLOSE
5V(S/W of A , B is OFF state)
OPEN
0V(S/W of A , B is ON state)