![LG GN-U262 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/lg/gn-u262/gn-u262_service-manual_1902520012.webp)
6. TROUBLESHOOTING
- 12-
6-1 COMPRESSOR AND ELECTRIC COMPONENTS
1
2
3
4
5
2
5
5
3
4
5
5
1
4
3
YES
YES
YES
NO
YES
YES
NO
NO
5
YES
NO
YES
Power
Source.
Remove the PTC-
Starter from the
Compressor and
measure the voltage
between Terminal C of
Compressor and
Terminals 5 or 6 of PTC.
No Voltage.
(Rating Voltage
±10%)?
Replace OLP.
Reconnect.
Replace
PTC-Starter.
Replace OLP.
O.K.
Check connection
condition.
OLP disconnected?
Advise the customer
to use a regular
Trans.
Replace Compressor.
OLP works within
30 sec. in forcible
OLP operation by
turning instant power
on and off.
Components start in
the voltage of Rating
Voltage ±10% below.
Applied voltage isn't
in the range of Rating
Voltage ±10%.
Check the resistance
among M-C, S-C and
M-S in Motor
Compressor.
Check the resistance of
two terminals in PTC-
Starter.
Check if applying
a regular OLP.
Measure minimum
starting voltage after 5
min. for balancing cycle
pressure and cooling the
PTC.
Check the
resistance of
Motor
Compressor.
Check the
resistance of
PTC-Starter.
Check OLP.
Check
starting state.
Содержание GN-U262
Страница 30: ...7 4 MAIN PWB ASS Y AND PARTS LIST 7 4 1 MAIN PWB ASS Y 30 1 R B52DZ R B55DZ ...
Страница 31: ...7 4 2 REPLACEMENT PARTS LIST 31 ...
Страница 33: ...7 5 PWB DIAGRAM 33 ...
Страница 34: ... 34 ...
Страница 36: ... optional parts 405C 405A 404A 329A 330B 332A 151A 154A 149B 140A 149A 131A 125A 110B 149C ...
Страница 37: ...109B 109B 201A 200A 203A 235A 231A 205A 241D 233A 230A 109C 210A 281D optional parts 243A 241B ...
Страница 38: ......