8-1-11 TEST Mode
1. The Test mode allows checking the PCB and the function of the product as well as finding out the defective part in case of
an error.
2. The test mode is operated by pressing two buttons at Display panel.
3. While in the test mode, the function control button is not recognized, but the recognition tone (beep~) sounds.
4. After exiting the test mode, be sure to reset by unplugging and then plugging in the appliance.
5. If an error, such as a sensor failure, is detected in the test mode, the test mode is cleared and the error code is
displayed.
6. While an error code is displayed, the test mode will not be activated.
- 24 -
MODE
MANIPULATION
CONTENTS
REMARKS
TEST1
TEST2
Reset
1) Continuous operation of the
Maximum test time:
COMPRESSOR
5 Minutes
2) Continuous operation of the freezer fan
3) STEPPING DAMPER OPEN
4) Defrosting Heater OFF
Reset to the previously setting
Before TEST MODE
The compressor will
Start after a 7-minute
Delay.
Push ICE PLUS
key and ADJUST key of
Freezer Temperature at the
same time over 3
seconds.
Push ICE PLUS
Key and ADJUST key of
Freezer Temperature at
the same time over 3
seconds in TEST MODE
1
Push ICE PLUS key and
AJUST key of Freezer
Temp. At the same time
over 3 seconds in TEST
MODE 2.
5) Every DISPLAY LED ON
1. COMP OFF
2. Freezer FAN OFF
3. STEPPING DAMPER CLOSE
4. Defrosting heater ON
5. DISPLAY LED 1, 3, 5, 7 ON
Reset if the temperature
of the defrosting sensor
is 46°F (8°C) or more.
* Freezer Fan RPM Variable Check:
In case the freezer fan is in operation when the ADJUST key in Refrigerator and Freezer Temp. Control are pressed for more
than one second at the same time freezer fan RPM changes. (For example if high speed, to normal speed or if normal speed,
to high speed for 30 seconds)
After 30 seconds, it turns to its original RPM.
*Demonstration MODE;
1. When the ICE PLUS key and ADJUST key of refrigerator temperature control are pressed for more than 3 seconds at the
same time temperature´s it converts to demonstration mode.
2. In this status, each LED is rotated with 1 second interval.
3. In this status, all loads are off (Compressor / Fan / Damper / Heater)
(Even is Demonstration Mode, the refrigerator Lamp automatic off function works normally and can be demonstrated)
4. It reset if you do again as clause.
Содержание GM-B208SS
Страница 36: ...8 5 MAIN PWB ASSEMBLY AND PARTS LIST 8 5 1 Main PWB Assembly 36 ...
Страница 37: ...8 5 2 Replacement Parts List 37 ...
Страница 38: ...8 5 3 PWB Assembly Display and parts list 38 ...
Страница 39: ...8 6 PWB DIAGRAM 39 8 6 1 PWB Main Assembly ...
Страница 40: ... 40 ...
Страница 45: ...August 2009 MFL62582001 ...