Appendix for refrigerators service maintenance manual

1.  Master should phone with client for appeal reasons clarification before visit.

2. Agree the accepted request with the senior master, for more accurate malfunction identification and for taking of reserve parts and 

    equipment needed.

3. Arriving to the customer inspect refrigerator for the presence of mechanical damages

In case of damages presence fix them on 

    the camera or any other digital technics.

4. The temperature indoors should be not below 16 degrees.

In case of malfunction concerned with lack of food cooling in refrigerator or freezer it is necessary to check filter-drain warming up 

(it should be warm). The fact that filter is cold indicates the system clogging or the leak of refrigerant. Check all visible parts of the pipes and 

pipes joints (solderings) with the leak detector designed for refrigerants R143a or R600a. At the time of diagnostics isolate the air flow 

directed from the fan of the condenser and compressor. In case of leak detection eliminate it.

For leak elimination it is necessary to:

- crop refueling pipe with pipe cutter;

- make pumping process for 10-15 minutes;

- solder again the area of leak by gas torch or cut this area by pipe cutter, expand pipe and solder it in the place cutting off earlier;   

- change filter to LG brand filter for refrigerant R134a or R600a (depends on refrigerant used by compressor);

- make pumping process for 10-15 minutes again;

- fill the unit with necessary refrigerant amount specified in grams on the label inside the product;

- remember that the pressure during the normal operating of refrigerator should be equal to

• «0+0.5Br» – for refrigerators with refrigerating unit operating with R134a refrigerant;

• «-0.5Br» – for refrigerators with refrigerating unit operating with R600a refrigerant.

If to cut off capillary pipe hardly below the filter-drain, flow capability of refrigerant will be bad at capillary pipe clogging from capillary side.

Oil with shavings of rubbing parts got into system from compressor can be the reason of capillary pipe clogging. 

There are 3 ways to eliminate capillary pipe clogging.

1. Bursting with nitrogen is the easiest and less expensive way. 

   Cut off the suction pipe near the compressor and the capillary pipe near the filter. Wind reductor on the nitrogen balloon and connect a 

   reinforced hose to reductor (it can be the hose for manometric rail). Hose must withstand at least 20atm. Connect a hose from the balloon 

   to manometric rail, and a hose from manometric rail (high pressure side) to suction pipe of refrigerator. Open the nitrogen bottle. The 

   pressure over 13 atmospheres for refrigerators with tube-on-sheet evaporator and the pressure over 20 atmospheres for refrigerators with 

   tubular evaporator are not recommended. Close balloon and block valve on a rail. It is recommended to wait at least 10-15 minutes. 

    Pressure decrease means that the obstruction began to be eliminated. If the pressure remains unchanged go to second method.

2. Punching hydraulic press. 

   Take the hydraulic press for punching a capillary pipe (you can buy it in auto stores, 

   they are used for pressing various parts.) Fill  the oil in hydraulic press, which use in the similar  refrigerator. 

   Then connect a hydraulic press to a capillary pipe and maximum pump  oil by hydraulic press in a 

   capillary tube. Obstruction is  eliminated not immediately, it takes time while the oil passed through 

   the capillary.

3. Bursting with dichloromethyl

   To solder a pipe 1 / 4  with schrader valve on cutting  capillary pipe near the filter. To unscrew from the valve spool. and  fill there from 

   syringe volume of 5-10 ml of dichloromethyl. Then, to wind the hose onto the valve. And serve the liquid refrigerant R22 through the 

   manometer rail, if there is not the R134.  Gas should not much, it needed only to dichloromethyl held in the capillary. Add nitrogen to 

   provide high pressure and wait. Dichloromethyl gradually dissolves clots and  at the beginning passage would be minimal. Operation should 

   be repeated 2-3 times.For greater effect, I recommend plugging your finger suction pipe to increase the pressure in the system, When the 

   sudden opening more oil comes out of it. Then you must do exactly the same operation on suction side, in the opposite direction.

When the oil is no longer out of the system, ALWAYS thoroughly purged with nitrogen through a suction pipe to remove residual 

dichloromethyl. Dichloromethyl dissolves varnish motor windings, that will lead to failure of the compressor. To verify that the obstruction is 

eliminated completely , must be submitted through 

Liquid refrigerant through the suction pipe and while the capillary pipe should be covered with ice and the oil should not come out of it. You 

can verify this by substituting under a stream of refrigerant, for example, pliers.

Be extremely careful when you cure the obstruction. Oil suddenly can shoot and dirty all around, recommend to cover the cloth.

APPENDIX FOR REFRIGERATORS SERVICE MAINTENANCE MANUAL 

45

Содержание GC-B379S*CA

Страница 1: ...3SECS FREEZER FREEZER EXPRESS FRZ ECO MODE FRIDGE CHILD LOCK DOOR ALARM Ref No GC B379S QA GC B409S QA Ref No GC B379S CA GC B409S CA REFRIGERATOR SERVICE MANUAL http biz lgservice com MODEL COLOR ...

Страница 2: ...9 DISPLAY REMOVE 10 ADJUSTMENT 10 COMPRESSOR 10 PTC STARTER 10 11 NOTE TO USE PTC STARTER 11 OLP OVER LOAD PROTECTOR 11 CIRCUIT DIAGRAM 12 TROUBLESHOOTING 13 COMPRESSOR AND ELECTRIC COMPONENTS 13 RELAY ASSEMBLY PTC AND OLP 14 ANOTHER ELECTRIC COMPONENT 15 SERVICE DIAGNOSIS CHART 16 REFRIGERATING CYCLE 17 19 MICOM FUNCTION PCB CIRCUIT EXPLANATION 20 34 EXPLODED VIEW 35 38 Contents APPENDIX FOR REFR...

Страница 3: ...ion of the refrigerator with the upper door open move with care to avoid hitting the upper door 8 When tilting the set remove any materials on the set especially the thin plates ex Glass shelf or books 9 When servicing the evaporator wear cotton gloves This is to prevent injuries from the sharp evaporator fins 10 Leave the disassembly of the refrigerating cycle to a specialized service center The ...

Страница 4: ...mp with the coupler And then turn the pump on for vacuum state Figure 3 Let the pump run until the low pressure gauge indicates the vacuum gauge pressure 0 absolute pressure 1atm or 760mmHg Recommended vacuum time is 30 min Charge the N2 gas in order to check for leakage from welding points and the LOKRING If leakages are found repair the defects and repeat the vacuum process After the system is c...

Страница 5: ...Shelf 3EA or 2EA Magic Crisper 1EA Vegetable Container 1EA 1 Ref No GC B379 409S CA 2 Ref No GC B379 409S QA ITEMS SPECIFICATIONS DIMENSIONS mm 595 W X643 D X1737 H 595 W X643 D X1907 H NET WEIGHT kg 69 75 COOLING SYSTEM Fan Cooling TEMPERATURE CONTROL Micom Control DEFROSTING SYSTEM Full Automatic DOOR FINISH Pre Coated Metal or Vinyl Coated Metal OUT CASE Painted Steel Sheet INNER CASE ABS INSUL...

Страница 6: ... Models GC 379S QA GC 379S CA GC 409S QA GC 409S CA Cover LED Multi air Flow Duct Glass Rem Shelf Vitamin Plus System Special models Vegetable Drawer Dairy Corner Special models Dairy Corner optional Guide Bottle optional Basket Door Guide optional Display optional PARTS IDENTIFICATION 6 ...

Страница 7: ...k Dairy Close both doors before removing hinge pins CAUTION Do not let either door drop to the floor Doing so could damage the Door Stop 1 2 3 5 4 A 6 A 7 5 9 8 10 11 14 12 6 13 5 How to Reverse the Door 1 After unscrewing the screw 2 of cover hinge 1 on the top take off cover hinge and disconnect cable 5 Only for the exterior display type models Unscrew bolts 3 which fasten upper hinge 4 and remo...

Страница 8: ...e which is fixated closer 23 of the freezer door B move closer 23 to the opposite side in appropriated place and fix it up Unscrew the screw 24 on the bottom of the case which is fixated emphasis 25 of the freezer door B move emphasis 25 to the opposite side in appropriated place and fix it up Move the upper cap 26 on the opposite side 7 Attach removed lower hinge 19 to the hole located on the opposit...

Страница 9: ...stops the emission of heat from the Heater 1 Pull out the Shroud F after removing the Grille 2 Separate the connector connected with the Defrost Control Assembly and replace new one Thermister Fuse Melting 6 HEATER SHEATH In this refrigerator Heater Sheath is used for defrosting heater During heating the temperature of heater rises about 300 350 Therefore be careful not to burn while servicing 1 A...

Страница 10: ...e 5 Be careful that dust humidity and flux welding don t inflow in the Compressor inside in replacing the Compressor Dust humidity and flux due to welding which inflows to Cylinder may cause lockage and noise 2 PTC STARTER 1 Composition of PTC Starter 1 PTC Positive Temperature Coefficient is a no contact semiconductor starting device which uses ceramic material and this material consists of ВаТiO...

Страница 11: ...out fail 3 Note to Use PTC Starter 1 Be careful not to allow over voltage and over current 2 No Strike Don t apply a forcible power or strike 3 Keep apart from any liquid If liquid such as oil or water away enter the PTC PTC materials it may break due to insulation breakdown of the material itself 4 Don t change PTC at your convenience Don t disassemble PTC and mold If the exterior to the PTC star...

Страница 12: ...12 CIRCUIT DIAGRAM P No MEZ62581565 ...

Страница 13: ...ressor Replace Compressor 3 Check the resistance of PTC Starter Check the resistance of two terminals in PTC Starter 4 Check OLP Check if applying a regular OLP OLP works within 30 sec in forcible OLP operation by turning instant power on and off 5 Check starting state Measure minimum starting voltage after 5 min for balancing cycle pressure and cooling the PTC Components start in the voltage of R...

Страница 14: ...a Tester or Whistone Bridge Figure 22 Separate the OLP from Compressor and check resistance value between two terminals of OLP with a Tester Figure 23 Check another electric components Replace PTC Observation value is 20 Ohm 220 240V 50Hz The resistance value is 0 or several hundreds The value is Check another electric components YES NO Replace OLP 33 TROUBLESHOOTING Mechanical Part 14 ...

Страница 15: ... current flowing in sub coil of Compressor Shorted Check capacity of OLP Lack of capacity The items described above are normal Coil of motor Compressor Running state of Compressor is poor Poor contacting Replace each component Fan motor doesn t run Check current flowing in the MOTOR MECH FAN Coil is shorted Check current flowing of the following components THERMISTOR FUSE MELTING Check current flowing...

Страница 16: ...ing air are high Is there gap in the door packed Wipe dew with a dry cloth This occurrence is solved naturally in low temperature and humidity Fill up the gap Abnormal noise generates Are the set positioned in a firm and even place Are any unnecessary objects set in the back side of the set Check if the Tray Drip is not firmly fixed Check if the cover of mechanical room in below and front side is tak...

Страница 17: ...mperature Equal to ambient temperature Normal discharging of refrigerant The capillary tube is faulty Normal discharging of Refrigerant MOISTURE CLOG Cooling operation stops periodically Flowing sound of Refrigerant is not heard and frost melts Low than ambient temperature Cooling operation restarts when heating the inlet of capillary tube DEFECTIVE COMPRESSION COMPRESSION NO COMPRESSION Freezer a...

Страница 18: ...in 3Omin after unpacking 2 Keep the unpacked drier at the temperature of80 100 C Don t keep the drier in a outdoors because humidity damages to it VACUUM 1 When measuring with pirant Vacuum gauge the charging М С vacuum degree is within 1 Torr 2 If the vacuum degree of the cycle inside is 10 Torr below for low pressure and 20 Torr for high pressure it says no vacuum leakage state 3 Vacuum degree o...

Страница 19: ...Figure 23 LOKRING Figure 24 LOKRING TOOL TOOL ASSEMBLY JAWS BOLT TUBE LOKRING LOKRING JOINT TROUBLESHOOTING Mechanical Part 19 ...

Страница 20: ...ON Quick freeze Economy mode Economy mode Temperature control in freezing compartment Temperature control in refrigeration compartment LED display lock button Loose fitting door alarm Quick freeze Temperature control in freezing compartment Temperature control in refrigeration compartment ...

Страница 21: ...0 20 21 5 23 23 15 15 17 5 20 20 unit temperature GC B379S QA GC B409S QA GC B379S CA GC B409S CA Setting temp GC B379S CA GC B409S CA classification First Power On 1time press 2times press 3times press 4times press 5times press 6times press 7times press 8times press 9times press NOTCH Setting temp classification First Power On 1time press 2times press 3times press 4times press 5times press NOTCH ...

Страница 22: ...on status during Eco Friendly freezer and fridge display is controlled by the minimal Notch control temperature of freezer refrigerator has to be at minimal Notch You can use this function for quick freezing This function is used when you want to freeze the food quickly Express Freezing on off method Press the Express Frz Button once The Express Frz Lamp turns on and the quick freezing starts If y...

Страница 23: ...Buzzer signal Display Micom gets the information about door open started from Main Micom the function of Door Alarm starts For stopping the signal you have to close the door LOCK function Display button lock LOCK on off method on press continuously the Lock Alarm button for 3 seconds or more off press continuously the Lock Alarm button for 3 seconds or more DISPLAY operation of LOCK function befor...

Страница 24: ...ot operate but the tones such as ding will sound 3 When the defect CODE removes the sign it returns to normal operation RESET 4 The defect CODE shows on the Refrigerator and Freezer Display PIC 2 3 GC B379S CA GC B409S CA 1 Defrosting starts each time the COMPRESSOR running time limit 50 hours s t r a t s g n i t s o r f e d n o r e w o p when the compressor running time reaches 4 hours 4 Defrosti...

Страница 25: ...re Freezer and Refigerator temperature setting Normal Setup temperature indication Normal Display Switch Failure of freezer sensor FS E Freezer sensor disconnection or short circuit Failure of Refigerator sensor rS E Refrigerator sensor disconnection or short circuit Check sensor wiring Failure of defrost sensor dS F Defrost sensor short circuit or disconnection Ambient sensor failure rt E Ambient...

Страница 26: ...FF Recycle ON OFF Recycle NO Classification Operation control COMP Fan of Engine section FAN of freezer Defrost heater Damper of refrigerator Normal 1 Freezer sensor failure Fridge sensor failure Defrost sensor failure Ambient sensor failure Defrost failure Main PCB Connection failure 2 3 4 5 6 7 15min ON 15min OFF No defrost Return immediately Sensor failure time 10min OPEN 15min CLOSE No compens...

Страница 27: ...n the display after reset the MICOM Return to normal mode Attention If Short made in TEST terminal the TEST 1 condition will maintain TEST function If the temperature is above than 45 C when the first time defrost sensor is power on the primary defrost conditions are proceed In case of temperature is lower than 45 C LQC heater check mode starts Attention If the sensor becomes above 45 C within 10 ...

Страница 28: ...uits for RELAY driving electricity 12Vdc and for supplying electricity to MICOM and IC 5Vdc The voltage in each part is as follows 7 If Short made in TEST terminal the TEST 1 condition will maintain Internal display Test 2 Mode PARTS VA1 CE2 CE3 VOLTAGE 230Vac 12Vdc 5Vdc 28 MICOM FUNCTION PCB CIRCUIT EXPLANATION ...

Страница 29: ... RESET CIRCUIT All the internal parts of MICOM IC1 return to the initial condition when the early power ON or apply power again in MICOM after temporary power failure As a result all the functions operate according to the early condition At the early period of power ON the LOW voltage is applied in the RESET terminal of MICOM for the fixed time The RESET terminal is 5V during the general operation...

Страница 30: ...4 LOAD BUZZER OPERATION 1 LOAD OPERATION CHECK 2 BUZZER OPERATION CHECK 51 50 MICOM FUNCTION PCB CIRCUIT EXPLANATION 30 ...

Страница 31: ...of each SENSOR is as follows SENSOR REFRIGERATOR SENSOR FREEZER SENSOR DEFROST SENSOR RT SENSOR CHECK POINT POINT A Voltage POINT B Voltage POINT C Voltage POINT D Voltage NORMAL 30 C 50 C SHORT OPEN 0 5V 4 5V 0V 5V Measure point CLOSE OPEN Refrigerator door NO 25 OF IC 1 MICOM 5V S W of 2 1 is OFF state 0V S W of 2 1 is ON state MICOM FUNCTION PCB CIRCUIT EXPLANATION 31 ...

Страница 32: ...SWITCH INPUT CIRCUIT The following circuit is a test switch input circuit for checking the refrigerator TEMPERATURE COMPENSATION P20 25 P65 MICOM FUNCTION PCB CIRCUIT EXPLANATION 32 ...

Страница 33: ...Inner MICOM DISPLAY GC B379S CA GC B409S CA GC B379S QA GC B409S QA 33 MICOM FUNCTION PCB CIRCUIT EXPLANATION ...

Страница 34: ...1D 108A 108A 281F 281B 501A 407B 102A 503A 402A 102C 102B 103B 281E 281A 610E 282B 283B EXPLODED VIEW REPLACEMENT PARTS LIST 610E GC B379S CA GC B409S CA 103A 109A 233A 231A 210A 281H 230A 239A 203A 230B 210B 128D 128C ...

Страница 35: ... 405C 301A EXPLODED VIEW REPLACEMENT PARTS LIST 401A 405A 329A 332A 315A 315B 315C 319A 319C 420A 329C 106B 104A 104C 420A 317A 318A 120E 120A 120B 401B 120D 323B 328A 327A 604F GC B379S CA GC B409S CA GC B379S QA GC B409S QA 310A 308A 309A 303D 319B ...

Страница 36: ...103E 241A 241C 235A 136E 155A 154G 151B 154D 154B 136A 136B 136C 136D GC B379S CA GC B409S CA GC B379S QA GC B409S QA 125A EXPLODED VIEW REPLACEMENT PARTS LIST ...

Страница 37: ...must withstand at least 20atm Connect a hose from the balloon to manometric rail and a hose from manometric rail high pressure side to suction pipe of refrigerator Open the nitrogen bottle The pressure over 13 atmospheres for refrigerators with tube on sheet evaporator and the pressure over 20 atmospheres for refrigerators with tubular evaporator are not recommended Close balloon and block valve o...

Страница 38: ......

Отзывы: