-12-
PTC
YES
NO
Poor starting or no
operating of the
Compressor.
First, separate the PTC from the
Compressor and check the voltage
between NO 5 and 6 in the PTC
with a multitester or Wheatstone
Bridge.
Observation value is
220~240V/50Hz :
33
Ω±
30%
The value is 0.
The value is
∞
.
Check another
electric
components.
Replace the PTC.
Normal
Abnormal
Abnormal
Replace the PTC.
Separate the OLP from the
Compressor and check
resistance value between two
terminals of OLP with Tester.
Check other electric
components.
Replace OLP.