Safety Precautions

ENGLISH

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by
the following indications.

Meanings of symbols used in this manual are as shown below.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage.

Be sure not to do.

Be sure to follow the instruction.

Always use a power plug and socket with
a ground terminal. 

• There is a risk of electric shock.

Do not use a defective or underrated
circuit breaker. Use the correctly rated
breaker and fuse. 

• There is risk of fire or electric shock .

Do not use a multi consent. Always use
this appliance on a dedicated cicuit and
breaker.

• Otherwise it can cause electric shock or fire.

For electrical work, contact the dealer, seller,
a qualified electrician, or an Authorized
Service Center. Do not disassemble or repair
the product by yourself.

• There is risk of fire or electric shock.

Always ground the product as per the
wiring diagram. Do not connect the
ground wire to gas or water pipes
lightening rod or telephone ground wire.

• There is risk of fire or electric shock.

Install the panel and the cover of control
box securely. 

• There is risk of fire or electric shock due to

dust , water etc.

Use the correctly rated breaker or fuse. 

• There is risk of fire or electric shock.

Do not modify or extend the power cable.
If the power cable or cord has scrathes or
skin peeled off or deteriorated then it
must be replaced.

• There is risk of fire or electric shock.

For installation, removal or reinstall ,
always contact the dealer or an
Authorized Service Center.

• There is risk of fire, electric shock, explosion, 

or injury.

Do not install the product on a defective
installation stand. Be sure that  the
installation area does not deteriorate with
age. 

• It may cause product to fall. 

Never install the outdoor unit  on a
moving base  or a place from  where  it
can fall down.

• The falling outdoor unit can cause damage or

injury or even death of a person.

When the product is soaked (flooded or
submerged) in water , contact an
Authorized Service Center for repair
before using it again.

• There is risk of fire or eletric shock.

In outdoor unit the step-up capacitor
supplies high voltage electricity to the
electrical components. Be sure to
discharge the capacitor completely
before conducting the repair work.

• An charged capacitor can cause electrical

shock.

When installing the unit, use the
installation kit provided with the product.

• Otherwise the unit may fall and cause severe

injury.

Be sure to use only those  parts which
are  listed in the svc  parts list. Never
attempt to modify the equipment. 

• The use of inappropriate parts can cause an

electrical shock, excessive heat generation or
fire.

Содержание G09LH

Страница 1: ...et and retain it for future reference The equipment complies with requirements of the Technical Regulation in terms of restrictions for the use of certain dangerous substances in electrical and electronic equipment P NO MFL41604505_v1 www lg com KZ O 02 0561 ENGLISH êìëëäàâ üáõä ìäêÄ çëúäÄ ...

Страница 2: ...stallation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temp...

Страница 3: ...ecurely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or an ...

Страница 4: ...ric shock Do not allow water to run into electric parts Install the unit away from water sources There is risk of fire failure of the product or electric shock Do not store or use or even allow flammable gas or combustibles near the product There is risk of fire Do not use the product in a tightly closed space for a long time Perform ventilation regularly Oxygen deficiency could occur and hence ha...

Страница 5: ...y If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace the all batteries in the remote control with new ones of the same type Do not mix old and new batteries or different types of...

Страница 6: ...nuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the applia...

Страница 7: ... and auto restart setting Timer Defrost mode Lights up during defrost mode or hot start operation Heat pump model only Lights up during outdoor unit operation Cooling model only Outdoor unit operation OUT DOOR Hot start operation Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out from unit In defrost mode unit stops heating operation for few minutes to remov...

Страница 8: ...h of the batteries 4 Use 2 AAA 1 5volt batteries NOTE 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth to clean them 3 In case ...

Страница 9: ...ment and set the desired up down airflow direction OPERATION MODE SELECTION BUTTON Used to select the operation mode OFF TIMER BUTTON Used to set the time of stopping operation START STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again ROOM TEMPERATURE SETTING BUTTONS INDOOR FAN SPEED SELECTION BUTTON JET COOL Used to start or stop the speed cooling S...

Страница 10: ...Each time the button is pressed the operation mode is shifted in the arrow direction Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C by 1 C Set the fan speed Select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted The display shows high fan speed Cooling Operation 1 2 3 4 Na...

Страница 11: ...is pressed the fan speed mode is shifted 1 2 3 This mode dehumidifies without overcooling During Healthy Dehumidification Operation If you select the dehumidification mode on the operation selection button the airconditioner starts to run the dehumidification function automatically setting the room temp and airflow volume to the best condition for dehumidification based on the sensed current room ...

Страница 12: ...1 hour to 7 hours Timer control Setting OFF TIMER CONTROL SETTING Press the Start Stop button The unit will respond with a beep To select Heating Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in...

Страница 13: ... the normal cooling mode from the JET COOL mode you just press either the operation mode selection button airflow volume selection or temp setting button or the JET COOL button again NOTE Press the Start Stop button The unit will respond with a beep Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes To cancel...

Страница 14: ...Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22 C 22 C 23 C 24 C Test operation During the TEST OPERATION the unit operates in cooling mode at high speed fan regardless of room temperature and resets in 18 minutes During test operation if remote controller signal is received the unit operates as remote controller sets If you want to use ...

Страница 15: ...rithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable as if enjoying natural breeze Always use the remote controller to adjust the up and down air flow direction Manually moving the vertical air flow direction louver by hand could damage the mechanism When the unit is shut off the up down airflow direction louver will close the air outlet ...

Страница 16: ...the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner or warm soapy water If dirt is not easily removed wash with a solution of detergent in luke warm water Dry well in shade after washing and reinstall the filters back in place Removal of Filters Open the front panel as shown Then pull the filter tab slightly forward to remove the air filter Gasoline Powder Pla...

Страница 17: ...t of the indoor outdoor unit are not blocked Do not overcool the room This is not good for the health and wastes electricity Make sure that the doors and windows are shut tight Avoid opening doors and windows as much as possible to keep the cool air in the room Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Clean the air filter reg...

Страница 18: ... damp smell exuded by the walls carpet furniture or cloth items in the room Condensation occurs when the airflow from the air conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vents...

Страница 19: ......

Отзывы: