- 11 -
ADJUSTMENT
All adjustment are thoroughly checked and corrected
when the monitor leaves the factory, but sometimes
several minor adjustment may be required.
Adjustment should be following procedure and after
warming up for a minimum of 30 minutes.
• Alignment appliances and tools.
- IBM compatible PC
- Programmable Signal Generator.
(eg. VG-819 made by Astrodesign Co.)
- Oscilloscope.
- White Balance Meter. (CA-110)
1. DDC Data Write Procedure-Analog
1) Use this procedure only when there is some
problem on Analog EDID data.
2) Run alignment program for M3200C on the IBM
compatible PC.
3) Select EEPROM
→
Analog EDID write command
and Enter.
4) This will write the Analog EDID data to EEPROM.
2. DDC Data Write Procedure-Digital
1) Use this procedure only when there is some
problem on Digital EDID data.
2) Run alignment program for M3200C on the IBM
compatible PC.
3) Select EEPROM
→
Digital EDID write command
and Enter.
4) This will write the Digital EDID data to EEPROM.
RS-232C
EXT.
220
IBM
Compatible PC
Parallel Port
Power inlet (required)
Power LED
ST Switch
Power Select Switch
(110V/220V)
Control Line
Not used
RS232C
PARALLEL
V-SYNC
POWER
ST
VGS
MONITOR
E
V-Sync On/Off Switch
(Switch must be ON.)
F
A
B
C
5V
E
F
A
B
C
15
10
5
5
6
9
1
1
1
14
13
25
6
5V
5V
4.7K
4.7K
4.7K
74LS06
74LS06
OFF
ON
OFF
ON
11
Figure 1. Cable Connection
Содержание Flatron M3200C
Страница 21: ... 21 EXPLODED VIEW 010 050 060 020 070 090 130 080 100 030 110 140 150 170 180 040 160 120 ...
Страница 34: ...SCHEMATIC DIAGRAM 34 1 AUDIO CTL AMP ...
Страница 35: ... 35 2 SCALER GM1501 ...
Страница 36: ... 36 3 MST9883 ...
Страница 37: ... 37 4 POWER CONNECTOR ...
Страница 38: ... 38 5 FAN CONTROL RS232C OUTPUT CONNECTOR ...
Страница 39: ... 39 6 UPD64012 K4S161622 ...
Страница 40: ... 40 7 MDIN150 MEMORY ...
Страница 41: ... 41 8 DSUB DVI D BA7657 ...
Страница 42: ... 42 9 CXA2040AQ TUNER M37272M6 AV JACK ...
Страница 43: ... 43 10 KEY CONTROL ...
Страница 44: ...Jun 2005 P NO 38289S0001T Printed in Korea ...