background image

Technical Information

A14

Display Modes

(Resolution)

User Modes

Video Memory Modes

The monitor has 26 memory locations for display modes, 16 of which
are factory preset to popular video modes.

Modes 17-26 are empty and can accept new video data. If the monitor
detects a new video mode that has not been present before or is not
one of the preset modes, it stores the new mode automatically in one
of the empty modes starting with mode 17.

If you use up the 10 blank modes and still have more new video modes,
the monitor replaces the information in the user modes starting with
mode 17.

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16

640 x 350
720 x 400
640 x 480
640 x 480
640 x 480
640 x 480
800 x 600
800 x 600
800 x 600
800 x 600
800 x 600
832 x 624

1024 x 768
1024 x 768
1024 x 768
1024 x 768

31.47
31.47
31.47
35.00
37.50
43.27
35.16
37.88
48.08
46.88
53.67
49.73
48.36
56.48
60.02
68.67

70
70
60
67
75
85
56
60
72
75
85
75
60
70
75
85

Display Modes (Resolution)

Horizontal Freq.

(kHz)

Vertical Freq.

(Hz)

VGA
VGA
VGA
MAC
VESA
VESA
VESA
VESA
MAC
VESA
VESA
MAC
VESA
VESA
VESA
VESA

Note :

This LCD monitor has been pre-adjusted to the video mode of 
VESA 1024x768 @60Hz.

Содержание FLATRON LCD 576LU

Страница 1: ...on On Screen Display OSD Control Adjustment On Screen Display OSD Selection and Adjustment Energy Saving Design Low Radiation Compliance MPR II Self Diagnostics Messages and DDC Display Data Channel Video Memory Modes Troubleshooting Service Specifications Communications Regulation Information Environmental Labelling of Personal Computers i A1 A7 A4 A5 A2 A8 A10 A9 A12 A14 A15 A16 A17 See back of ...

Страница 2: ... 31 and 69kHz and vertical scan frequencies between 56 85Hz The microprocessor based intelligence allows the monitor to operate in each frequency mode with the precision of a fixed frequency monitor We accomplished to adapt the advanced design and technology to the monitor Soft touch buttons on the front panel are simple and allow you to conveniently adjust a variety of image controls The absolute...

Страница 3: ...ome consult with your dealer Overloaded AC outlets and extension cords are dangerous So are frayed power cords and broken plugs They may result in a shock or fire hazard Call your service technician for replacement Do not Open the Monitor There are no user serviceable components inside There are Dangerous High Voltages inside even when the power is OFF Contact your dealer if the monitor is not ope...

Страница 4: ... strike the Active Matrix LCD with anything hard as this may scratch mar or damage the Active Matrix LCD permanently Do not press the LCD screen with your finger for a long time as this may incur some afterimages Some dot defects may appear on the screen like Red Green or Blue spots on the screen However this will have no impact or effect on the monitor performance If possible use the VESA 1024x76...

Страница 5: ...t the other end of the monitor signal cable to the rear panel of Macintosh computer through a Macintosh adapter and then tighten screws Connect the plug from the AC adapter into the base of the monitor Connect one end of the AC power cord to the AC adapter and the other end to a properly grounded AC outlet that is easily accessible and close to the monitor Power on the computer then the monitor If...

Страница 6: ...le the computer is running or unplug them while maintaining Plug and Plug auto detection and configuration This monitor has an integrated self powered USB hub allowing up to 4 other USB devices to be attached it 1 Connect the upstream port of the monitor to the downstream port of the USB compliant PC or another hub using the USB cable Computer must have a USB port 2 Connect the USB compliant perip...

Страница 7: ...te the USB hub function the monitor must be connected to a USB compliant PC OS or another hub with the USB cable enclosed When connecting the USB cable check that the shape of the connector at the cable side matches the shape at the connecting side When the monitor is not plugged into an electric socket the peripherals connected to the downstream ports will not operate Even if the monitor is in a ...

Страница 8: ...ront View Rear View Location and Function of Controls 2 4 V 24V DC Power Connector D sub Signal Connector Power Button Power Indicator OSD Button Buttons AUTO SET Button DC Power Connecter USB upstream port USB downstream port ...

Страница 9: ...power button This indicator lights up green when the monitor operates normally If the monitor is in DPM Energy Saving mode stand by suspend power off this indicator color changes to amber Power Indicator Front Panel Controls AUTO Function When you press AUTO SET button before using OSD menu the screen disappears momentarily Then it is adjusted automaticaly to optimized configuration If screen conf...

Страница 10: ...ollow these steps Press the OSD Button then the main menu of the OSD appears To acces a control use the or Buttons When the icon you want becomes highlighted press the AUTO SET Button Use the Buttons to adjust the item to the desired level Accept the changes by pressing the AUTO SET Button Exit the OSD by Pressing the OSD Button NOTE Allow the monitor to stabilize for at least 30 minutes before ma...

Страница 11: ... PRESET RED GREEN BLUE 9300K 6500K POSITION 61 39 Brightness Used to adjust the brightness of the screen Contrast Adjust the display to the contrast desired PRESET RED GREEN BLUE 9300K 6500K To appear the displays color temperature 9300K Slightly bluish white 6500K Slightly reddish white To set your own color levels To set your own color levels To set your own color levels Vertical Position To mov...

Страница 12: ...of the display This item allows you to remove any horizontal noise and clear or sharpen the image of characters To choose the language in which the control names are displayed This function displays the image in its original size or enlarged size so as to fit in the full screen of the LCD panel To adjust position of the OSD window on the screen To select beep ON or OFF Used to rotate OSD window 90...

Страница 13: ...cant energy by reducing power consumption during periods of non use When the PC goes into the energy saving mode the monitor will go into a suspended operation state indicated by the Power LED light changing from a green color to an amber color After an extended period in the suspended mode the monitor will then enter a semi OFF mode to conserve more energy In the semi OFF mode or DPMS OFF mode as...

Страница 14: ...l be highlighted alerting you to check the signal cable connections OUT OF RANGE This OSD may appear to inform you that the signal being sent to the monitor is not within its frequency range In this case you would need to check the resolution and refresh rate you have your video card set to and adjust to be within the range of the monitor DDC is a communication channel over which the monitor autom...

Страница 15: ...ill have more new video modes the monitor replaces the information in the user modes starting with mode 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 640 x 350 720 x 400 640 x 480 640 x 480 640 x 480 640 x 480 800 x 600 800 x 600 800 x 600 800 x 600 800 x 600 832 x 624 1024 x 768 1024 x 768 1024 x 768 1024 x 768 31 47 31 47 31 47 35 00 37 50 43 27 35 16 37 88 48 08 46 88 53 67 49 73 48 36 56 48 60 02 ...

Страница 16: ...he frequency of the signal from the video card is outside the operating range of the monitor Horizontal Frequency 31kHz 69kHz Vertical Frequency 56Hz 85Hz Use the graphics board s utility software to change the frequency setting Refer to the manual for graphics board You can change the setup to the supported resolution using the Safe Mode Press the F8 key during booting the system The power LED is...

Страница 17: ...her controls may result in damage and often requires extensive work by a qualified technician to restore the monitor to normal operation The monitor has been dropped or the cabinet has been damaged The monitor exhibits a distinct change in performance Snapping or popping from the monitor is continuous or frequent while the monitor is operating It is normal for some monitors to make occasional soun...

Страница 18: ...rate Sync H Sync V Sync Pin Signal D Sub 1 2 3 4 5 6 7 8 Red Green Blue Ground Self Test Red Ground Green Ground Blue Ground Pin Signal D Sub 9 10 11 12 13 14 15 N C Ground Ground SDA H Sync V Sync SCL 11 6 1 5 15 10 N C No Connection NOTE No 5 Pin have to ground on the PC side Use only the AC adapter supplied with the monitor AC 100 240V 50 60Hz 1 2A 0 6A DC 24V 2 0A ...

Страница 19: ...307 x 230mm 12 1 x 9 1inch Input Form Separate RGB Analog 0 714Vp p 75ohm Positive Resolution max VESA 1024 x 768 85Hz Width 39 4 cm 15 5 inches Height min left 39 78 cm 15 7 inches max left 47 28 cm 18 6 inches Applies to 577LH only Depth 21 47 cm 8 45 inches DC 24V 1 8A Net 5 7 kg 12 57 lbs Applies to 577LH only 5 49 kg 12 1 lbs Applies to 576LU only Down 0 Up 30 Operating condition Temperature ...

Страница 20: ...a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user s or your authority to operate the equipment Only peripherals digital input output devices terminals printers etc certified to comply with the Class B li...

Страница 21: ...es environment ergonomics usability reduction of electric and magnetic fields energy consumption and electrical safety In many countries environmental labelling has become an established method for encouraging the adaptation of goods and services to the environment The main problem as far as computers and other electronics equipment are concerned is that environmentally harmful substances are used...

Страница 22: ...ow you will find a brief summary of the environmental requirements met by this product The complete environmental criteria document may be ordered from TCO Development SE 114 94 Stockholm Sweden Fax 46 8 782 92 07 Email Internet development tco se Current information regarding TCO 99 approved and labelled products may also be obtained via the Internet using the address http www tco info com Flame ...

Страница 23: ... or electronics components associated with the labelled unit There is however one exception Mercury is for the time being permitted in the back light system of flat panel monitors as there today is no commercially available alternative TCO aims on removing this exception when a mercury free alternative is available CFCs freons The relevant TCO 99 requirement states that neither CFCs nor HCFCs may ...

Отзывы: