- 14 -
220
IBM
Compatible PC
PARALLEL PORT
Power inlet (required)
Power LED
ST Switch
Power Select Switch
(110V/220V)
Control Line
Not used
RS232C
PARALLEL
V-SYNC
POWER
ST
VGS
MONITOR
E
E
V-Sync On/Off Switch
(Switch must be ON.)
F
F
A
A
B
B
C
C
15
10
5
5
6
9
1
1
1
14
13
25
6
5V
5V
5V
4.7K
4.7K
4.7K
74LS06
74LS06
OFF
ON
OFF
ON
11
Video Signal
Generator
Figure 1. Cable Connection
SERVICE OSD
1) Turn off the power switch at the front side of the display.
2) Wait for about 5 seconds and press MENU, POWER switch with 1 second interval.
3) The SVC OSD menu contains additional menus that the User OSD menu as described below.
a) Auto Color : W/B balance and Automatically sets the gain and offset value.
b) NVRAM INIT : EEPROM initialize.(24C08)
c) CLEAR ETI : To initialize using time.
d) AGING : Select Aging mode(on/off).
e) R/G/B-9300K : Allows you to set the R/G/B-9300K value manually.
f) R/G/B-6500K : Allows you to set the R/G/B-6500K value manually.
g) R/G/B-Offset : Allows you to set the R/G/B-Offset value manually.(Analog Only)
h) R/G/B-Gain : Allows you to set the R/G/B-Gain value manually.(Analog Only)
i) MODULE : To select applied module.
Содержание FLATRON L1721B
Страница 22: ...EXPLODED VIEW L1721B 20 010 020 050 060 070 080 090 100 130 110 120 030 040 ...
Страница 24: ...EXPLODED VIEW L1921B 22 010 020 140 090 080 070 060 050 100 030 120 040 110 130 ...
Страница 28: ...SCHEMATIC DIAGRAM 26 1 TSU56AL TSU16AL 1 Waveforms U201 96 97 3 R216 R778 H Sync 3 R217 R781 V Sync 1 3 ...
Страница 29: ... 27 2 MICOM 2 U501 43 H SYNC 2 U501 44 V SYNC Waveforms 2 ...
Страница 30: ... 28 3 POWER ...
Страница 31: ... 29 4 CONNECTOR JACKS 3 Waveforms R216 R778 H Sync 3 R217 R781 V Sync 3 ...
Страница 32: ...Blank Page1 ...
Страница 33: ...Blank Page2 ...
Страница 34: ...May 2005 P NO 38289S0001D Printed in Korea ...