DIAGNOSTIC TEST
ACTIVATING THE DIAGNOSTIC TEST MODE
1. UNIT must be in standby (unit plugged in, display off)
2. Press POWER while pressing MORE TIME and LESS TIME simultaneously.
3. Press START/PAUSE button to advance through diagnostics.
To check pump operation:
When pressed 4 times in the test mode, If the AD value of the pump is higher than 10 on the display, the pump is normal.
If it is lower than 10, E5 error will be displayed.
1.This TEST should be used for Factory test /Service test. Do not use this DIAGNOSTIC TEST other than specified.
2.Activating the Heater manually with the Door open may trip the Thermostat attached to the Heater, therefore do not
activate it manually. (Do not press the door switch to operate the heater while the door is open )
Pressing the
START/PAUSE
None
Standard
PGM Ver (8E8-V008E8)
V00
8E9 (Elec Type)
898 (Gas Type)
Thermistor open
Thermistor shorted
tE1
AG Thermistor open or shorted
tE4
tE2
Pump Error
Pump runs
E5
Power off
OO
Motor runs
Displays Moisture Sensor Operation
If moisture sensor is contacted with
damp cloth. The display number is
below180innormalcondition
30 = High
moisture
239 = Low
moisture
Current Temp.
(5~70)
Current Temp.
(5~70)
Pump AD valve
(11~255)
Electric control
&
Temperature sensor
ELECTRIC TYPE
Motor+Heater1(2700W)
GAS TYPE
Motor
ELECTRIC TYPE
Motor+Heater2
(5400W)
GAS TYPE
Motor+Gasvalve
Once
Motor+Controller
Motor, Pump, Heater2 off
Loads, Controller off
Motor+Pump+
Heater2(runs for 1sec)
(Heater1 off)
Twice
3 times
4 times
5 times
6 times
CHECKING
ACTION
DISPLAY
CHECKPOINT
ELECTRIC TYPE Heater 1 is energized
- 2700 W
GAS TYPE is not opened
(Temperature in the drum is displayed in
degrees C.)
ELECTRIC TYPE: Heater 1 and heater 2 are
energized - 5400 W
GAS TYPE: Gas valve is energized (Temperature in
the drum is displayed in degrees C.)
DUAL SENSOR FAILURE CHECK :
Values of TEMPERATURE2 and HUMIDITY are
‘000’, the display shows SE ERROR.
Test 1
120V AC Electrical supply
Caution
Trouble Symptom
Measurement
Condition
When measuring power, be sure to wear insulated gloves to avoid an
electric shock.
No power was applied to Controller. (LED,LCD Display off)
With Dryer Power On; Connector linked to Controller.
Check the outlet, is the voltage
110V ~ 125V AC?
YES
NO
• Check the fuse
or circuit breaker.
Check if the voltage measured between
Connector BK2 or WH2-
(Black Wire)
Linked to the Controller and WH1-
(White Wire) Is 110~125V?
YES
NO
1
1
2
BK2 or WH2 WH1
BK
WH
• Check if Power
Cord is properly
connected.
• Reconnect the
controller.
Replace controIler.
Check if the Controller wire is
disconnected.
Check if Terminal Block and Power Cord
are connected (Check Plug ).
- Does Power Cord N neutral line match
to center terminal N neutral line?
YES
NO
L (Black)
L (Red)
N (White)